Force-GT DIN rail power supply with 24V 5A output (120W) from 90-264 Vac or 127-375 Vdc. Metal case and convection cooling, operating -40 to +70 °C. With a constant-current mode, a DC OK signal and conformal-coated boards.
Price and availability on request
Key features
- Surge capacity (with SPD) up to 6 kV
- Compliant with IEC 61000-4-6 at 20 V for semiconductor requirements
- Universal AC input voltage range
- Built-in constant current circuit for charging applications
- Full load operating temperature up to 60°C
- Ultra-Slim design
- Long life electrolytic capacitor
- Built-in DC OK relay and LED indicator
- Conformal coating on PCBAs to protect against common dust and pollutants
- Compliant with 80 PLUS Gold for 115 V Industrial
Specifications
| Series | Force-GT Series |
|---|---|
| Mounting | DIN rail |
| Output Current | 5A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 24-28 Vdc |
| Output Power | 120W |
| Line Regulation | ± 0.5% @ 115 Vac & 230 Vac |
| Load Regulation | ± 0.5% |
| PARD | < 100 mVpp @ 0°C to +70°C / < 300 mVpp @ -30°C to 0°C |
| Start-up Time | 300 ms typ. @ 115 Vac & 230 Vac |
| Hold-up Time | 35 ms typ. @ 115 Vac & 230 Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115 Vac & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz) |
| Start-up with Capacitive Loads | 10,000 µF Max |
| Rise Time | 30 ms typ. @ 115 Vac & 230 Vac |
| Nominal Input Voltage | 100-240 Vac |
|---|---|
| Input Voltage Range | 90-264 Vac |
| Nominal Input Frequency | 50-60 Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 127-375 Vdc |
| Input Current | 1.2 A typ. @ 115 Vac, 0.6 A typ. @ 230 Vac |
| Input Power (Standby Mode) | 0.5 W max @ 115 Vac & 230 Vac |
| Efficiency at 100% load | 93.5 typ. @ 230 Vac |
| Inrush Current | 40 A typ. @ 230 Vac |
| Power Factor at 100% load | > 0.95 @ 115 Vac & > 0.92 @ 230 Vac |
| Leakage Current | < 0.5 mA @ 240 Vac |
| Case Chassis / Cover | Metal |
|---|---|
| Indicator | Green LED DC OK |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 600 V / 30 A) |
| Output Terminal | 3 Pins (Rated 600 V / 30 A) |
| Signal Terminal | 2 Pins (Rated 300 V / 6 A) |
| Noise Sound Pressure Level (SPL) | < 25 dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input: AWG 18-12 / Output: AWG 18-12 / DC OK: AWG 22-16 |
| Unit Weight | 0.5 kg (1.10 lb) |
| Dimensions | 123.6 x 30 x 116.8 mm / 4.87” x 1.18” x 4.60” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10Hz to 500Hz; 4G peak; 60 min per axis for all X, Y, Z directions |
|---|---|
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Temperature: > 60°C de-rate power by 2.5 % / °C / Input Voltage: < 100Vac de-rate power by 1% / Vac |
| Operating Humidity | 5 to 90% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
| Overvoltage | <34 V, SELV Output, Latch Mode |
|---|---|
| Overload / Overcurrent | 105 - 150% of rated load current, Auto-recovery / Continuous current limit Mode (Vo > 80%) |
| Over Temperature | Latch Mode |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Protection Against Shock | Class I with Primary Earth connection |
| Internal Fuse | T3.15 A / 250 V |
| MTBF | Telcordia SR-332: > 700,000 hrs / I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C |
|---|---|
| Expected Cap Life Time | 10 years (115 Vac & 230 Vac, 50% load @ 50°C) |
| Electrical Safety | CB scheme: IEC 62368-1, IEC 60950-1, IEC 61010-1/-2-201 / TUV Bauart: EN/BS EN 62368-1, EN/BS EN 61010-1/-2-201 / UL/cUL: UL 62368-1, UL 61010-1/-2-201 / EAC: TP TC 004/2011 / BSMI: CNS14336-1 / CCC: GB4943.1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 4.0 kVac / Input to Ground: 2.0 kVac / Output to Ground: 1.5 kVac / Output to DC OK: 500 Vac |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016 |
| Emission | (CE & RE) / CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR32, EN/BS EN 61204-3, KS C 9832 / Compliance to FCC Title 47, EN 61000-6-3 : Class B |
|---|---|
| Immunity | EN/BS EN 55035, KS C 9835, EN/BS EN 61000-6-2 / Compliance to EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A & Class D |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
| Component Power Supply for General Use | EN/BS EN 61204-3 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.