Delta DRC-24V100W1RZ 24V 3.83A 91.92W DIN Rail Power Supply, CHROME II Series
- Brand
- Delta
- Model number
- DRC-24V100W1RZ
- Category
- DIN-Rail Power Supplies
CHROME II DIN rail power supply with 24V 3.83A output (91.92W) from 85-264 Vac. Plastic case and convection cooling, operating -30 to +70 °C. With class II double insulation and NEC Class 2 rating.
Price and availability on request
Key features
- Class II, Double Isolation (No Earth connection is required)
- Mechanical dimensions are designed to meet DIN 43880 for building automation
- Low no load power consumption and compliance with DOE VI efficiency standard
- NEC Class 2 / Limited Power Source (LPS) certified
- Over Voltage Category III
Specifications
| Series | CHROME II Series |
|---|---|
| Mounting | DIN rail |
| Output Current | 3.83A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 21.6-26.4 Vdc |
| Output Power | 91.92W |
| Line Regulation | ± 0.5% @ 115 Vac & 230 Vac |
| Load Regulation | ± 0.5% |
| PARD | < 150 mVpp @ 0°C to +70°C / < 450 mVpp @ -30°C to 0°C |
| Start-up Time | 300 ms typ. @ 115 Vac & 230 Vac |
| Hold-up Time | 12 ms typ. @ 115 Vac & 60 ms typ. 230 Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115 Vac & 230 Vac input, 10-100% load / (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz) |
| Start-up with Capacitive Loads | 8,000 µF Max |
| Rise Time | 30 ms typ. @ 115 Vac & 230 Vac |
| Nominal Input Voltage | 100-240 Vac |
|---|---|
| Input Voltage Range | 85-264 Vac |
| Nominal Input Frequency | 50-60 Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | < 1.8A @ 115 Vac / < 1.2A @ 230 Vac |
| Efficiency at 100% load | 88.5% typ. @ 115 Vac / 91.0% typ. @ 230 Vac |
| Inrush Current | 70 A typ. @ 230 Vac |
| Leakage Current | < 0.25 mA @ 240 Vac |
| Power Dissipation | 0% load: / 0.15 W typ. @ 115 Vac / 0.21 W typ. @ 230 Vac |
| Case Chassis / Cover | Plastic |
|---|---|
| Indicator | Green LED DC OK |
| Cooling System | Convection |
| Input Terminal | M2.5 x 2 Pins (Rated 300 V / 16 A) |
| Output Terminal | M2.5 x 4 Pins (Rated 300 V / 16 A) |
| Noise Sound Pressure Level (SPL) | < 25 dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input: AWG 24-12 / Output: AWG 18-12 |
| Unit Weight | 0.23 kg (0.51 lb) |
| Dimensions | 87.5 x 70 x 55.0 mm / 3.44” x 2.76” x 2.17” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2 G; 10 min per cycle, 60 min for X, Y, Z direction |
|---|---|
| Operating Temperature | -30°C to +70°C (-40°C Cold Start) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Temperature: > 50°C de-rate power by 2% / °C / Input Voltage: < 100Vac de-rate power by 1% / Vac |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft) |
| Pollution Degree | 2 |
| Over Voltage Category | II / (Compliance to EN 62477-1 OVC III with 2,000 Meters altitude) |
| Overvoltage | < 36 V, SELV Output Latch Mode |
|---|---|
| Overload / Overcurrent | 4.17A max., Auto-recovery Continuous current limit Mode (Vo > 80%) |
| Over Temperature | Latch Mode |
| Short Circuit | Hiccup Mode, Non-Latching / (Auto-Recovery when the fault is removed) |
| Degree of Protection | IP20 |
| Protection Against Shock | Class II (No Primary Earth connection is required) |
| Internal Fuse | T4 A / 250 V |
| MTBF | Telcordia SR-332: > 700,000 hrs I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C |
|---|---|
| Expected Cap Life Time | 10 years (115 Vac & 230 Vac, 50% load @ 40°C) |
| Electrical Safety | CB scheme: IEC 62368-1, IEC/EN/BS EN 61010-1/-2-201, IEC 60335-1, IEC/EN/BS EN 61558-1/-2-16 / TUV Bauart: EN/BS EN 62368-1, EN/BS EN 60335-1 / UL/cUL: UL 62368-1, UL 61010-1/-2-201 / EAC: TP TC 004/2011 / BSMI: CNS 15598-1 / BIS: IS 13252 (Part 1) / CCC: GB4943.1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output 4.0 kVac |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016 |
| Emission | CISPR 32, EN 55032, EN 61000-6-4, AS/NZS CISPR32, EN 61204-3, KS C 9832 / Compliance to FCC Title 47, EN 61000-6-3 : Class B |
|---|---|
| Immunity | EN 55035, KS C 9835 , EN 61000-6-2 / Compliance to EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN 61000-3-3 |
| Component Power Supply for General Use | EN 61204-3 |
| Tags | NEC Class 2 |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.