Delta DRC-24V100W1AG 24V 3.8A 91.2W DIN Rail Power Supply, CHROME Series
- Brand
- Delta
- Model number
- DRC-24V100W1AG
- Category
- DIN-Rail Power Supplies
CHROME DIN rail power supply with 24V 3.8A output (91.2W) from 90-264Vac or 125-375Vdc. Plastic case and convection cooling, operating -25 to +71 °C. With NEC Class 2 rating.
Price and availability on request
Key features
- Class II Double Isolation (No Earth connection is required)
- Universal AC input voltage range and full power up to 55°C
- Power will not de-rate for the entire input voltage range
- Efficiency > 89.0% @ 230 Vac
- Can be installed in compact cabinets
- NEC Class 2 and Limited Power Source (LPS) approvals
- Conforms to harmonic current IEC/EN 61000-3-2, Class A
- Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508
Specifications
| Series | CHROME Series |
|---|---|
| Mounting | DIN rail |
| Output Current | 3.8A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 22-24Vdc |
| Output Power | 91.2W |
| Line Regulation | < 0.5% (@ 90-264Vac input, 100% load) |
| Load Regulation | < 1.0% (@ 90-264 Vac input, 0-100% load) |
| PARD | < 100mVpp |
| Start-up Time | < 2,000ms @ nominal input (100% load) |
| Hold-up Time | > 10 ms @ 115 Vac, / > 60 ms @ 230 Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 90-264 Vac input, 10-100% load / (Slew Rate: 0.1 A/μs, 50% duty cycle @ 5 Hz to 100 Hz) |
| Start-up with Capacitive Loads | 3,000µF Max |
| Rise Time | < 70ms @ nominal input (100% load) |
| Nominal Input Voltage | 100-240Vac |
|---|---|
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Nominal DC Input Voltage | 125-250Vdc |
| DC Input Voltage Range | 125-375Vdc |
| Input Current | < 2.20A @ 115Vac, / < 1.00A @ 230Vac |
| Efficiency at 100% load | > 87.0% @ 115Vac, / > 89.0% @ 230Vac |
| Inrush Current | < 30A @ 115Vac, / < 60A @ 230Vac |
| Leakage Current | < 0.25mA @ 240Vac |
| Power Dissipation | 0% load: < 0.4 W @ 115 Vac & 230 Vac / 100% load: < 13.6 W @ 115 Vac, < 11.2 W @ 230 Vac |
| Case Chassis / Cover | Plastic |
|---|---|
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 2 Pins (Rated 300V/25A) |
| Output Terminal | 4 Pins (Rated 300V/25A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input/Output: AWG 20-12 |
| Unit Weight | 0.35 kg (0.77 lb) |
| Dimensions | 91 x 89.9 x 55.6 mm / 3.58” x 3.54” x 2.19” |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10-500Hz @ 19.6m/S² (2G peak); / 10 min per cycle, 60 min for all X, Y, Z directions |
|---|---|
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 4G for a duration of 22ms, / 3 shocks for each 3 directions, 9 times in total |
| Operating Temperature | -25°C to +71°C |
| Storage Temperature | -25°C to +85°C |
| Power De-rating | > 55°C de-rate power by 2.5% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Operating Altitude | 0 to 2,000 Meters (6,560 ft) |
| Pollution Degree | 2 |
| Over Voltage Category | II |
| Overvoltage | < 34.8V, SELV Output, Latch Mode |
|---|---|
| Overload / Overcurrent | > 102~108% of rated load current, Fold Forward Mode (current rises, voltage drops), Non-Latching (Auto-Recovery) |
| Over Temperature | > 75°C Surrounding Air Temperature @ 100% load, Latch Mode |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Degree of Protection | IP20 |
| Protection Against Shock | Class II (No Primary Earth connection is required) |
| MTBF | > 500,000 hrs. as per Telcordia SR-332 I/P: 100 Vac, O/P: 100% load, Ta: 35°C |
|---|---|
| Expected Cap Life Time | 10 years (115Vac & 230Vac, 50% load @ 40°C) |
| Electrical Safety | TUV Bauart: EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) / CB scheme: IEC 60950-1, IEC 62368-1, Limited Power Source (LPS) / UKCA: BS EN 62368-1 |
|---|---|
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
| Galvanic Isolation | Input to Output: 3.0KVac |
| Industrial Control Equipment | UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E338991) |
| Safety Entry Low Voltage | SELV (EN 60950) |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 |
| BIS | IS 13152-1 |
| Emission | (CE & RE) / Generic Standards: CISPR 32, EN/BS EN 55032, FCC Title 47: Class B |
|---|---|
| Immunity | Generic Standards: EN/BS EN 55024 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC/EN/BS EN 61000-3-3 |
| Tags | NEC Class 2 |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.