CHROME DIN rail power supply with 12V 4.5A output (54W) from 90-264Vac or 125-375Vdc. Plastic case and convection cooling, operating -25 to +71 °C. With class II double insulation and NEC Class 2 rating.

Price and availability on request

Request a quote

Sent with the product details: Delta DRC-12V60W1AZ 12V 4.5A 54W DIN Rail Power Supply, CHROME Series.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Class II, Double Isolation (No Earth connection is required)
  • Universal AC input voltage range
  • Power will not de-rate for the entire input voltage range
  • Efficiency > 86.0% @ 115Vac & 230Vac
  • Can be installed in compact cabinets
  • NEC Class 2 and Limited Power Source (LPS) approvals for selected models
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508 for selected models

Specifications

Product
SeriesCHROME Series
MountingDIN rail
Output
Output Current4.5A
Output Voltage12V
Output Voltage Adjustment Range11.5-14.0Vdc
Output Power54W
Line Regulation< 0.5% (@ 90-264Vac input, 100% load)
Load Regulation< 1.0% (@ 90-264Vac input, 0-100% load)
PARD< 100mVpp
Start-up Time< 2,000ms @ nominal input (100% load)
Hold-up Time> 16ms @ 115Vac, / > 60ms @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 90-264Vac input, 10-100% load / (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 100Hz)
Start-up with Capacitive Loads3,000μF Max
Rise Time< 70ms @ nominal input (100% load)
Input
Nominal Input Voltage100-240Vac
Input Voltage Range90-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
DC Input Voltage Range125-375Vdc
Input Current< 1.50A @ 115Vac, / < 1.00A @ 230Vac
Efficiency at 100% load> 86.0% @ 115Vac & 230Vac
Inrush Current< 30A @ 115Vac, / < 60A @ 230Vac
Leakage Current< 0.25mA @ 240Vac
Power Dissipation0% load: < 0.35W @ 115Vac & 230Vac / 100% load: < 8.75W @ 115Vac & 230Vac
Mechanical
Case Chassis / CoverPlastic
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Input Terminal2 Pins (Rated 300V/25A)
Output Terminal4 Pins (Rated 300V/25A)
Noise Sound Pressure Level (SPL)< 25dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput/Output: AWG 20-12
Unit Weight0.22 kg (0.49 lb)
Dimensions91 x 71 x 55.6 mm / 3.58” x 2.80” x 2.19”
Environment
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10-500Hz @ 19.6m/S² (2G peak); 10 min per cycle, 60 min for all X, Y, Z directions
Shock Test (Operating)IEC 60068-2-27, Half Sine Wave: 4G for a duration of 22ms, 3 shocks for each 3 directions, 9 times in total
Operating Temperature-25°C to +71°C
Storage Temperature-25°C to +85°C
Power De-rating> 55°C de-rate power by 2.5% / °C
Operating Humidity5 to 95% RH (Non-Condensing)
Operating Altitude0 to 2,000 Meters (6,560 ft)
Pollution Degree2
Over Voltage CategoryII
Protections
Overvoltage< 17.4V, SELV Output, Latch Mode
Overload / Overcurrent< 8A, Hiccup Mode, Non-Latching (Auto-Recovery)
Over Temperature> 75°C Surrounding Air Temperature @ 100% load, Latch Mode
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Degree of ProtectionIP20
Protection Against ShockClass II (No Primary Earth connection is required)
Reliability
MTBF> 500,000 hrs. as per Telcordia SR-332 (I/P: 100Vac, O/P: 100% load, Ta: 35°C)
Expected Cap Life Time10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety
Electrical SafetyDRC-12V60W1AZ, DRC-12V60W1AG: / TUV Bauart: EN 60950-1, EN 62368-1 / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) / CB scheme: IEC 60950-1, IEC 62368-1, Limited Power Source (LPS) / / DRC-12V60W1CZ: / UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) / CB scheme: IEC 60950-1, IEC 62368-1, Limited Power Source (LPS)
CEDRC-12V60W1AZ, DRC-12V60W1AG: / In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic IsolationInput to Output: 3.0KVac
Industrial Control EquipmentDRC-12V60W1AZ, DRC-12V60W1AG: / UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E338991)
Safety Entry Low VoltageSELV (EN 60950)
UKCAIn conformance with 2016 No. 1101. The Electrical Equipment (Safety) Regulations 2016 and 2016 No. 1091 The Electromagnetic Compatibility Regulations 2016
EMC
Emission(CE & RE) / Generic Standards: CISPR 32, EN 55032, FCC Title 47: Class B
ImmunityGeneric Standards: EN 55024
Harmonic Current EmissionsIEC/EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN 61000-3-3
Other
TagsNEC Class 2