| Sensing type | Through-beam |
|---|
| Sensing distance | 15 m |
|---|
| Sensing target | Opaque materials |
|---|
| Min. sensing target | ≥ Ø 15 mm |
|---|
| Response time | AC/DC power, relay contact output model: ≤ 20 ms DC power, solid state (transistor) output model: ≤ 1 ms |
|---|
| Light source | Infrared |
|---|
| Peak emission wavelength | 850 nm |
|---|
| Sensitivity adjustment | YES (Adjuster) |
|---|
| Timer mode | OFF, ON Delay, OFF Delay, One Shot Delay mode selectable (Switch): 0.1 to 5 sec (Adjuster) |
|---|
| Operation mode | Light ON mode - Dark ON mode selectable (Switch) |
|---|
| Indicator | Operation indicator (yellow), self-diagnosis indicator (green), power indicator (yellow) |
|---|
| Unit weight | Based on the standard model, timer model: weight + 1 g |
|---|
| AC/DC power | ≈ 225 g |
|---|
| DC power | ≈ 211 g |
|---|
| Output method | AC/DC power, relay contact output |
|---|
| Power supply | 24-240 VAC ± 10 % 50/60 Hz 24-240 VDC ± 10 % (ripple P-P: ≤ 10 %) |
|---|
| Power / current consumption | ≤ 3 VA |
|---|
| Control output | Relay contact output |
|---|
| Contact capacity | 250 VAC 3 A of resistance load, 30 VDC 3 A of resistance load |
|---|
| Contact composition | 1c |
|---|
| Relay life cycle | Mechanical: ≥ 50,000,000 Electrical: ≥ 100,000 |
|---|
| Insulation resistance | ≥ 20 MΩ (500 VDC megger) |
|---|
| Insulation type | Double or strong insulation (dielectric voltage between the measured input and the power : 1.5 kV) |
|---|
| Noise immunity | ± 1,000 VDC the square wave noise (pulse width: 1 ㎲) by the noise simulator |
|---|
| Dielectric strength | Between the charging part and the case: 1,500 VAC 50/60 Hz for 1 min |
|---|
| Vibration | 1.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours |
|---|
| Vibration (malfunction) | 1.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 10 min |
|---|
| Shock | 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times |
|---|
| Shock (malfunction) | 100 m/s² (≈ 10 G) in each X, Y, Z direction for 3 times |
|---|
| Ambient illuminance (receiver) | Sunlight: ≤ 11,000 lx, incandescent lamp: ≤ 3,000 lx |
|---|
| Ambient temperature | -20 to 55 ℃, storage: -25 to 70 ℃ (no freezing or condensation) |
|---|
| Ambient humidity | 35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation) |
|---|
| Protection rating | IP65 (IEC standard) |
|---|
| Connection | Terminal type |
|---|
| Material | Case, lens cover: PC, sensing part: Acrylic, bracket: SPCC, bolt: SCM, nut: SCM |