Autonics ATS8W-23 W 38 × H 42 mm Twin Analog Timer ATS8W-23
Autonics ATS8W-23 W 38 × H 42 mm twin analog timer (ATS8W / 11W Series): Relay output, 24 VAC 50 / 60 Hz, 24 VDC supply. Order code note: 24VAC/DC.
Price and availability on request
Key features
- Wide power supply range: 100 - 240 VAC 50 / 60 Hz, 24 - 240 VDC universal / 24 VAC 50 / 60 Hz, 24 VDC / 12 VDC
- Various output operations (6 operation modes)
- Multi time range (12 types of time range)
- Twin timer to set ON / OFF time individually
- Close and DIN rail mounting with the dedicated socket (PS-M8) width 41 mm (ATS8W)
- Easy installation / maintenance with the dedicated bracket for DIN 48 × 48 mm
Specifications
| Series | ATS8W / 11W Series |
|---|---|
| Order code description | 24VAC/DC |
| Catalogue model group | ATS□W-2□ |
| Function | ON / OFF Flicker operation |
|---|---|
| Return time | ≤ 100 ms |
| Time operation | Power ON Start |
| Control output | Relay |
| Contact type | Time limit DPDT (2c), Instantaneous SPDT (1c) + Time limit SPDT (1c) |
| Contact capacity | 250 VAC 3 A, 30 VDC 3 A resistive load |
| Error | Repeat: ≤ ± 0.2% ± 10 ms SET: ≤ ± 5% ± 50 ms Voltage: ≤ ± 0.5% Temp.: ≤ ± 2% |
| Unit weight (packaged) | ≈ 75 g (≈ 100 g) |
| Power supply | 24 VAC 50 / 60 Hz, 24 VDC |
| Permissible voltage range | 90 to 110 % of rated voltage |
| Power consumption | AC: ≤ 4.5 VA DC: ≤ 2 W |
| Insulation resistive | ≥ 100 MΩ (500 VDC megger) |
| Dielectric strength | Between the charging part and the case : 3,000 VAC at 50 / 60 Hz for 1 min |
| Noise immunity | ± 500 V square-wave noise by noise simulator (pulse width 1 ㎲) |
| Vibration | 0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 1 hour |
| Vibration (malfunction) | 0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 10 min |
| Shock | 300 m/s2 (≈ 30 G) in each X, Y, Z direction for 3 times |
| Shock (malfunction) | 100 m/s2 (≈ 10 G) In each X, Y, Z direction for 3 times |
| Relay life cycle | Mechanical: ≥ 10,000,000 operations Electrical: ≥ 100,000 operations (250 VAC 3 A resistive load) |
| Ambient temperature | -10 to 55 ℃, storage: -25 to 65 ℃ (no freezing or condensation) |
| Ambient humidity | 35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation) |
| Sold separately | 8-pin controller socket: PG-08, PS-08(N), PS-M8; 11-pin controller socket: PG-11, PS-11(N) |
|---|