Multispan
143 Multispan products listed. For prices and availability, send an enquiry.
Products
-
Enquire about DC-24
DC-24 DC Amp + Volt Combined Meter, 72 x 72
Compact 72 x 72 mm DC meter showing current (-999 to 9999 A via shunt), voltage (-1500 to 1500 V DC) and power, with RS-485 Modbus. 24-270 V AC/DC supply.
-
Enquire about DC-142
DC-142 DC Amp + Volt Combined Meter, 96 x 96
DC panel meter showing current, voltage and power together: -999 to 9999 A through a shunt, -1500 to 1500 V DC and up to 9999 kW, with two protection relays and RS-485 Modbus.
-
Enquire about DGMR-132
DGMR-132 DG Monitoring Relay
Panel relay that watches mains and DG supplies, with over / under voltage, asymmetry, phase loss and phase sequence protection and auto reset. 96 x 96 mm.
-
Enquire about DI-17
DI-17 On / Off Delay Timer, Universal Supply, 17.5 mm
17.5 mm DIN-rail timer for on-delay, off-delay and cyclic on / off, 0.5 s to 30 hours, with one changeover relay and 24 V AC/DC or 230 V AC supply.
-
Enquire about DI-22+
DI-22+ On / Off Delay Timer, Universal Supply, 22.5 mm
22.5 mm DIN-rail timer for on-delay, off-delay and cyclic on / off, 0.5 s to 30 hours, with one changeover relay and 24 V AC/DC or 230 V AC supply.
-
Enquire about DMR-162
DMR-162 Demand Controller
Class 0.5 maximum demand controller and multifunction meter for single and three-phase systems, with THD up to the 32nd order, pulse output and RS-485 Modbus, to keep load within the contract demand.
-
Enquire about DPS24-2.5A
DPS24-2.5A Power Supply 24V 2.5A, DPS Series
DIN-rail switching power supply, 24 V DC at 2.5 A (60 W) from a 100-270 V AC input, in a polycarbonate case, with overload, over-voltage, short-circuit and over-temperature protection.
-
Enquire about DT-60S
DT-60S On / Off Delay Timer, Fixed Range
Simple DIN-rail on / off delay timer with fixed 10, 30 or 60 second ranges and one changeover relay. 22.5 mm wide.
-
Enquire about ECT-35D
ECT-35D Earth Leakage Relay with Built-in CBCT (35 mm)
Earth leakage relay with its own 35 mm core balance CT, so no separate CBCT is needed. 30 mA to 3 A, digital setting of leakage and trip delay, one changeover relay and test / reset.
-
Enquire about EDC-351
EDC-351 DC Energy Meter, DIN Rail
DIN-rail DC energy meter with selectable shunt (1 to 9999 A DC), voltage from -1000 to 1000 V DC and power up to 9999 kW, with optional RS-485 Modbus. 35 mm wide.
-
Enquire about EFR-35
EFR-35 Earth Fault Relay, DIN Rail
DIN-rail digital earth fault relay working with an external CBCT, with programmable trip delay, two relays and front or terminal test / reset. 100-270 V AC/DC supply.
-
Enquire about ELR-19N
ELR-19N Earth Leakage Relay, Panel Mount
Panel-mount earth leakage relay with 4+4 digital display of leakage and set current, one changeover relay, fail-safe or non-fail-safe mode and RS-485 Modbus. 96 x 96 mm.
-
Enquire about ELR-35
ELR-35 Earth Leakage Relay, Digital DIN Rail
Digital DIN-rail earth leakage relay, 30 mA to 30 A, with 3+3 LED display, programmable trip delay, leakage level LEDs at 25 / 50 / 75% of set point and fail-safe or non-fail-safe mode.
-
Enquire about EM-1P
EM-1P Single Phase Energy Meter
Single-phase 2-wire digital energy meter for 30-300 V AC (L-N), with RS-485 Modbus communication available.
-
Enquire about EN-19N
EN-19N Earth to Neutral Voltage Relay, Panel Mount
Panel-mount relay showing earth-to-neutral voltage (0-10 V AC range) with a programmable relay trip and optional RS-485 Modbus. 96 x 96 mm, 100-270 V AC/DC supply.
-
Enquire about ENR-35-M1
ENR-35-M1 Earth to Neutral Voltage Relay, DIN Rail
DIN-rail relay that monitors earth-to-neutral voltage in single and three-phase systems, with 3+3 LED display, auto or manual trip reset, test mode, one changeover relay and RS-485 Modbus.
-
Enquire about EPM-14-M1
EPM-14-M1 Three Phase Energy Meter
Three-phase 4-wire energy meter with separate kWh and kW displays, pulse output and RS-485 Modbus; optional relay on kW. Also available as EM-10.
-
Enquire about EPM-35
EPM-35 Energy Power Meter, DIN Rail
DIN-rail energy and power meter for single-phase or three-phase 3 or 4-wire systems (20-300 V L-N, 35-520 V L-L), with RS-485 Modbus. 100-270 V AC/DC supply.
-
Enquire about EPM-70
EPM-70 DIN Rail Digital Multifunction Meter
DIN-rail multifunction meter for single and three-phase systems with THD up to the 32nd order, import / export energy, pulse output and RS-485 Modbus. PT primary up to 520 kV.
-
Enquire about ER-2K
ER-2K Earth Leakage Relay, Analog DIN Rail
Analog DIN-rail earth leakage relay, 30 mA to 30 A, with leakage set point and trip delay set by knobs, one changeover relay and front or terminal test / reset.
-
Enquire about FLT-L16
FLT-L16 16-Channel Fault Annunciator
Touch-screen fault annunciator for 16 potential-free NO / NC fault contacts, with two changeover relays and RS-485 Modbus. 320 x 240 resistive touch display; 100-270 V AC/DC supply.
-
Enquire about FRQ-11
FRQ-11 Single Phase Frequency Meter
Digital frequency meter for single-phase supplies, 45.0 to 65.0 Hz from a 0-300 V AC input. 96 x 96 mm panel size; also made in 72 and 48 mm sizes.
-
Enquire about FRT-22U
FRT-22U Forward Reverse Timer
DIN-rail forward / reverse timer for motors: forward and reverse times from 0.1 s to 10 hours with a 1-100 s pause, two changeover relays and universal 12-240 V DC / 20-240 V AC supply.
-
Enquire about LC-1046D
LC-1046D Length Counter
Panel length counter for proximity sensors or an encoder (MMC-1000 version), showing total length to 6 digits and line speed in metres per minute, with one changeover relay.