Selec TWCT Tape Wound Current Transformer TWCT
- Brand
- Selec
- Model number
- TWCT
- Category
- Current Transformers
Selec TWCT tape wound current transformer: 30A to 1600A primary, 5A secondary.
Price and availability on request
Key features
- Tape wound CT ranging from 30A-1600A
- Terminal Output
- Rated burden 1.5VA to 10VA
- Inner Diameter: 35, 55, 65, 110, 120mm
- Class of accuracy 0.5 to 5
- Applicable standard IEC 61869-2
Specifications
| Features | Terminal Output |
|---|---|
| Rated Primary Rating | 30A to 1600A |
| Rated Secondary Output | 5A |
| Rated Burden (VA) | 1.5 to 10 |
| Accuracy | 0.5 to 5 |
| Operating Frequency | 50/60Hz |
| System Voltage | 720V Maximum |
| Applicable Standard | IEC-61869-2 |
| TWCT-T-D35-30/5A-VA1.5-CL5 | Wire Aperture DIA35, Current Ratio 30/5, Burden in VA 1.5, Accuracy Class 5 |
|---|---|
| TWCT-T-D35-50/5A-VA5-CL5 | Wire Aperture DIA35, Current Ratio 50/5, Burden in VA 5, Accuracy Class 5 |
| TWCT-T-D35-75/5A-VA5-CL5 | Wire Aperture DIA35, Current Ratio 75/5, Burden in VA 5, Accuracy Class 5 |
| TWCT-T-D35-100/5A-VA5-CL1 | Wire Aperture DIA35, Current Ratio 100/5, Burden in VA 5, Accuracy Class 1 |
| TWCT-T-D35-150/5A-VA5-CL1 | Wire Aperture DIA35, Current Ratio 150/5, Burden in VA 5, Accuracy Class 1 |
| TWCT-T-D55-150/5A-VA5-CL1 | Wire Aperture DIA55, Current Ratio 150/5, Burden in VA 5, Accuracy Class 1 |
| TWCT-T-D55-200/5A-VA5-CL1 | Wire Aperture DIA55, Current Ratio 200/5, Burden in VA 5, Accuracy Class 1 |
| TWCT-T-D55-250/5A-VA5-CL1 | Wire Aperture DIA55, Current Ratio 250/5, Burden in VA 5, Accuracy Class 1 |
| TWCT-T-D55-300/5A-VA5-CL1 | Wire Aperture DIA55, Current Ratio 300/5, Burden in VA 5, Accuracy Class 1 |
| TWCT-T-D55-400/5A-VA5-CL1 | Wire Aperture DIA55, Current Ratio 400/5, Burden in VA 5, Accuracy Class 1 |
| TWCT-T-D65-500/5A-VA5-CL1 | Wire Aperture DIA65, Current Ratio 500/5, Burden in VA 5, Accuracy Class 1 |
| TWCT-T-D65-600/5A-VA5-CL1 | Wire Aperture DIA65, Current Ratio 600/5, Burden in VA 5, Accuracy Class 1 |
| TWCT-T-D110-800/5A-VA10-CL0.5 | Wire Aperture DIA110, Current Ratio 800/5, Burden in VA 10, Accuracy Class 0.5 |
| TWCT-T-D110-1000/5A-VA10-CL0.5 | Wire Aperture DIA110, Current Ratio 1000/5, Burden in VA 10, Accuracy Class 0.5 |
| TWCT-T-D120-1000/5A-VA10-CL0.5 | Wire Aperture DIA120, Current Ratio 1000/5, Burden in VA 10, Accuracy Class 0.5 |
| TWCT-T-D120-1200/5A-VA10-CL0.5 | Wire Aperture DIA120, Current Ratio 1200/5, Burden in VA 10, Accuracy Class 0.5 |
| TWCT-T-D120-1600/5A-VA10-CL0.5 | Wire Aperture DIA120, Current Ratio 1600/5, Burden in VA 10, Accuracy Class 0.5 |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.