Selec TWCT Tape Wound Current Transformer TWCT

Brand
Selec
Model number
TWCT

Selec TWCT tape wound current transformer: 30A to 1600A primary, 5A secondary.

Price and availability on request

Request a quote

Sent with the product details: Selec TWCT Tape Wound Current Transformer TWCT.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Tape wound CT ranging from 30A-1600A
  • Terminal Output
  • Rated burden 1.5VA to 10VA
  • Inner Diameter: 35, 55, 65, 110, 120mm
  • Class of accuracy 0.5 to 5
  • Applicable standard IEC 61869-2

Specifications

Specifications
FeaturesTerminal Output
Rated Primary Rating30A to 1600A
Rated Secondary Output5A
Rated Burden (VA)1.5 to 10
Accuracy0.5 to 5
Operating Frequency50/60Hz
System Voltage720V Maximum
Applicable StandardIEC-61869-2
Ordering codes
TWCT-T-D35-30/5A-VA1.5-CL5Wire Aperture DIA35, Current Ratio 30/5, Burden in VA 1.5, Accuracy Class 5
TWCT-T-D35-50/5A-VA5-CL5Wire Aperture DIA35, Current Ratio 50/5, Burden in VA 5, Accuracy Class 5
TWCT-T-D35-75/5A-VA5-CL5Wire Aperture DIA35, Current Ratio 75/5, Burden in VA 5, Accuracy Class 5
TWCT-T-D35-100/5A-VA5-CL1Wire Aperture DIA35, Current Ratio 100/5, Burden in VA 5, Accuracy Class 1
TWCT-T-D35-150/5A-VA5-CL1Wire Aperture DIA35, Current Ratio 150/5, Burden in VA 5, Accuracy Class 1
TWCT-T-D55-150/5A-VA5-CL1Wire Aperture DIA55, Current Ratio 150/5, Burden in VA 5, Accuracy Class 1
TWCT-T-D55-200/5A-VA5-CL1Wire Aperture DIA55, Current Ratio 200/5, Burden in VA 5, Accuracy Class 1
TWCT-T-D55-250/5A-VA5-CL1Wire Aperture DIA55, Current Ratio 250/5, Burden in VA 5, Accuracy Class 1
TWCT-T-D55-300/5A-VA5-CL1Wire Aperture DIA55, Current Ratio 300/5, Burden in VA 5, Accuracy Class 1
TWCT-T-D55-400/5A-VA5-CL1Wire Aperture DIA55, Current Ratio 400/5, Burden in VA 5, Accuracy Class 1
TWCT-T-D65-500/5A-VA5-CL1Wire Aperture DIA65, Current Ratio 500/5, Burden in VA 5, Accuracy Class 1
TWCT-T-D65-600/5A-VA5-CL1Wire Aperture DIA65, Current Ratio 600/5, Burden in VA 5, Accuracy Class 1
TWCT-T-D110-800/5A-VA10-CL0.5Wire Aperture DIA110, Current Ratio 800/5, Burden in VA 10, Accuracy Class 0.5
TWCT-T-D110-1000/5A-VA10-CL0.5Wire Aperture DIA110, Current Ratio 1000/5, Burden in VA 10, Accuracy Class 0.5
TWCT-T-D120-1000/5A-VA10-CL0.5Wire Aperture DIA120, Current Ratio 1000/5, Burden in VA 10, Accuracy Class 0.5
TWCT-T-D120-1200/5A-VA10-CL0.5Wire Aperture DIA120, Current Ratio 1200/5, Burden in VA 10, Accuracy Class 0.5
TWCT-T-D120-1600/5A-VA10-CL0.5Wire Aperture DIA120, Current Ratio 1600/5, Burden in VA 10, Accuracy Class 0.5

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.