Key features

  • Control outputs: 6, 8 or 12
  • Auto-initialisation: detects number of capacitor banks, bank kVAr value and phase correction angle
  • Bank kVAr programmable as direct value, control series or auto-detected value
  • Intelligent bank switching for equal use of capacitors; capacitor health monitoring
  • Each output can be set to permanently ON, permanently OFF or auto
  • Manual mode for diagnosis and test run to measure connected bank kVAr
  • Alarm relay for high / low voltage, under / over current, over temperature, frequency faults, voltage / current harmonics, under and over compensation
  • Measures V, A, Hz, power, energy (import / export), demand, THD and individual harmonics up to 31st
  • High contrast 16 x 2 LCD with backlight
  • Optional Modbus (RS485) output and RTC

Specifications

Control
Number of outputs6, 8 or 12 (up to 12 max.)
Alarm output1
Target PF range0.8 lead to 0.8 lag
Switching threshold30 to 100%
Connecting / disconnecting time10 to 1800 s
Discharge time60 to 1800 s
Input
Nominal input voltage240 V AC
Voltage measuring range30 - 550 V AC
Nominal input current1 A / 5 A AC; CT primary 1 A up to 9999 A
Current range3 mA starting, 10 mA operating, max. 6 A
Frequency40 - 70 Hz
Auxiliary supply
Voltage110 V AC to 550 V AC, 40 to 70 Hz
Burden
Voltage / current / auxiliary< 0.2 VA per phase / < 0.6 VA per phase / < 13 VA
Accuracy
Voltage, current±0.5% of nominal value
Frequency±0.15% of mid frequency
Power and energy±1.0% of nominal value
THD±1.0% of applied value
Protection defaults
Under / over voltage85% (75 - 90%) / 115% (105 - 115%) of V nom
Under / over frequency6% (2 - 10%)
Under / over current2% (1 - 3%) / 110% (60 - 120%) of CT primary
V-THD / I-THD7% (1 - 25% / 1 - 99%)
Standards
ComplianceIEC 61326-1:2012, IEC 62053-21, IEC 61010-1-2010; installation category III
High voltage test2.2 kV AC, 50 Hz for 1 minute
General
Operating temperature-10 to +60 °C
Storage temperature-20 to +65 °C
Relative humidity0 - 90% non condensing
Front protectionIP 54 (IEC 60529)
Dimensions144 x 144 x 56 mm
Ordering
Order codePF40-B1H[6 / 8 / A = 12 relays]A[R / Z Modbus][R / Z RTC]0000RI, e.g. PF40-B1HAARR0000RI

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.