Rishabh EQ 48 Moving Iron AC Ammeter / Voltmeter, 90°, 48 x 48 mm

Brand
Rishabh
Model number
EQ 48
Category
Panel Meters

Moving iron panel meter, 48 x 48 mm, 90° scale: true RMS AC voltage or current, class 1.5, interchangeable scales, CT / PT operated versions; UL 94 V-0 polycarbonate case.

Price and availability on request

Request a quote

Sent with the product details: Rishabh EQ 48 Moving Iron AC Ammeter / Voltmeter, 90°, 48 x 48 mm.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • True RMS AC voltage or current, practically independent of waveform
  • Scale interchangeability: dials slide out and in from the front
  • Near linear scale above 10% of full scale
  • Ammeter over range: none, 2 times or 6 times nominal current
  • Glass filled polycarbonate case, flame retardant and drip proof (UL 94 V-0)
  • Knife edge pointer; easily replaceable glass and bezel
  • Easy installation with swivel screws; several meters can share one cut-out (mosaic mounting)

Specifications

Measurement
Measured quantityAC voltage or current
Standard rangesAC voltage 6 V ... 600 V (750 V except EQ 48); AC current 100 mA ... 60 A (100 A except EQ 48); for use on .../1 A or .../5 A CT and .../100 V or .../110 V PT
Frequency range15 ... 100 Hz (voltage), 15 ... 400 Hz (current)
Accuracy class1.5 (IS 1248 / IEC 51)
Power consumptionVoltmeters < 4.5 VA; ammeters < 15 A < 0.5 VA, > 15 A < 0.8 VA
Scale
Pointer deflection0 ... 90°
Scale length41 mm
Safety
Rated insulation / proof voltage660 V / 2 kV
Installation category300 V CAT III
General
Operating temperature-5 ... +50 °C
Storage temperature-40 ... +70 °C
Front size48 x 48 mm
Panel cut-out45 x 45 mm
Weight (approx.)0.1 kg
CaseMoulded square case, glass filled polycarbonate (UL 94 V-0)
EnclosureIP 52 case; IP 20 terminals with back cover
Options
Options on orderAntiglare glass; red, yellow, blue or white bezel; blank or special dials; red or green markings
Supplied with
ContentsMeter with full sized polycarbonate back cover (terminal protection)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.