Megger MIT525 5 kV Diagnostic Insulation Resistance Tester
- Brand
- Megger
- Model number
- MIT525
- Category
- Insulation Resistance Testers
5 kV diagnostic insulation tester to 10 TΩ with IR, DAR, PI, DD, step voltage and ramp tests, PI Predictor, time-stamped memory and USB download; mains or Li-ion battery, CAT IV 600 V.
Price and availability on request
Key features
- Insulation resistance up to 10 TΩ at 5 kV
- Full suite of test modes: IR, timed IR, DAR, PI, DD, SV and ramp test
- PI predictor function (PIp): predicts the 10-minute PI, starting as early as 3 minutes into the test
- 3 mA short circuit current and 3 mA noise rejection
- Advanced memory with recall to screen and real time clock for time / date stamped results
- Insulation temperature (measured separately) can be saved with each result
- USB download to PowerDB and CertSuite Asset
- Dedicated voltmeter function (30 V to 660 V)
- Dual-case design: tough outer case and inner fire retardant case, IP65 with the lid closed
- Operates from battery or AC mains supply
- Rapid charge Li-ion battery: more than 60 minutes of testing after a 30-minute charge
- Large backlit display with digital and analogue readings, two rotary switches
- Graphical quick start guide inside the lid
- Locking HV insulated plugs and non-removable test clips
- Safety rated CAT IV 600 V to 3000 m
Specifications
| Test voltages | 250 V, 500 V, 1000 V, 2500 V, 5000 V and user defined (40 V to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps) |
|---|---|
| Accuracy (23 °C) from 1 MΩ to | ±5%: 1 TΩ at 5000 V, 500 GΩ at 2500 V, 200 GΩ at 1000 V, 100 GΩ at 500 V, 50 GΩ at 250 V; ±20%: 10 TΩ at 5000 V, 5 TΩ at 2500 V, 2 TΩ at 1000 V, 1 TΩ at 500 V, 500 GΩ at 250 V |
| Test modes | IR, IR(t), DAR, PI, SV, DD, Ramp test |
| Interference (noise rejection) | 3 mA from 450 V to 5 kV |
| Short circuit / charge current | 3 mA |
| Test voltage accuracy | +4%, -0%, ±10 V nominal test voltage at 1 GΩ load (0 °C to 30 °C) |
| Display range | Analogue 100 kΩ to 10 TΩ; digital 10 kΩ to 10 TΩ |
| Capacitor charge | <3 s/μF at 3 mA to 5 kV |
| Capacitor discharge | <250 ms/μF to discharge from 5 kV to 50 V |
| Capacitance range | 10 nF to 25 μF (test voltage above 500 V), ±10% ±5 nF |
| Current range | 0.01 nA to 6 mA, ±5% ±0.2 nA at all voltages (20 °C) |
| Insulation test alarm | 100 kΩ to 10 GΩ |
| Timer range | Up to 99 minutes 59 seconds, 15 second minimum setting |
| Range | 30 V to 660 V AC or DC, 45 Hz - 65 Hz |
|---|---|
| Accuracy | ±3%, ±3 V |
| Power | Rechargeable 10.8 V, 5.2 Ah Li-ion battery (meets IEC 62133:2003), or 90-264 V rms, 47-63 Hz, 100 VA AC supply |
|---|---|
| Battery charge time | 2.5 hours deep discharge, 2 hours normal discharge |
| Battery life | 6 hours (typical) continuous testing at 5 kV with a 100 MΩ load |
| Operating temperature | -20 °C to 50 °C |
| Storage temperature | -25 °C to 65 °C |
| Humidity | 90% RH non-condensing at 40 °C |
| IP rating | IP65 (lid closed), IP40 (lid open) |
| Safety | CAT IV 600 V to 3000 m altitude; meets IEC 61010-1 |
| Dimensions | 315 x 285 x 181 mm |
| Weight | 4.5 kg |
| Capacity | 5.5 hours logging at 5 second intervals, with time / date stamp |
|---|---|
| Interface | USB type B (device), fully isolated |
| Real time output | 1 Hz output readings (V, I, R) |
| Contents | Power lead; USB cable; 3 m lead set with medium size insulated clips; Calibration certificate |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.