Megger MIT410/2 CAT IV Insulation and Continuity Tester

Brand
Megger
Model number
MIT410/2

Handheld 1 kV insulation tester with five test voltages from 50 V to 1000 V, readings up to 200 GΩ, PI and DAR, fast 0.01 Ω to 1 MΩ continuity and 600 V True RMS voltage; CAT IV 600 V, IP54.

Price and availability on request

Request a quote

Sent with the product details: Megger MIT410/2 CAT IV Insulation and Continuity Tester.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Insulation testing at 50 V, 100 V, 250 V, 500 V and 1000 V, up to 200 GΩ at 1000 V
  • Stabilised insulation test voltage, maintained within -0% +2% (industry standard 10-20%)
  • Polarisation Index (PI, 10 min / 1 min) and Dielectric Absorption Ratio (DAR, 60 s / 15 s or 60 s / 30 s)
  • Timed testing and insulation test lock
  • PASS / FAIL indication on limit alarms
  • Leakage current display
  • Single auto-ranging continuity range from 0.01 Ω to 1 MΩ, with 200 mA or 20 mA test current and automatic bi-directional testing
  • True RMS AC and DC voltage measurement to 600 V with automatic frequency display
  • Analogue arc plus dual digital display (result and test voltage, leakage current, frequency or test mode)
  • Live circuit detection inhibits insulation testing above 25 V, 30 V, 50 V, 75 V or 100 V (default 50 V), even if the fuse has failed
  • Over-moulded case sealed to IP54, including battery and fuse compartment
  • Runs on 6 AA alkaline or NiMH rechargeable cells

Specifications

Insulation
Test voltages50 V, 100 V, 250 V, 500 V, 1000 V
Range and accuracy10 GΩ at 50 V, 20 GΩ at 100 V, 50 GΩ at 250 V, 100 GΩ at 500 V, 200 GΩ at 1000 V; ±2% ±2 digits plus 4.0% (50 V), 2.0% (100 V), 0.8% (250 V), 0.4% (500 V) or 0.2% (1000 V) per GΩ
Resolution0.1 kΩ
Short circuit / charge current2 mA +0% -50% to EN 61557-2 (2007)
Open circuit voltage-0% +2% ±2 V
Test current1 mA at min. pass value of insulation, 2 mA max.
Leakage current10% ±3 digits
Timer60 second countdown timer
Analogue display1 GΩ full scale
Continuity
Range0.01 Ω to 1000 kΩ
Accuracy±3% ±2 digits (0 to 100 Ω), ±5% ±2 digits (100 Ω to 500 kΩ)
Test current200 mA (-0 mA +20 mA) from 0.01 Ω to 4 Ω, or 20 mA
Open circuit voltage5 V ±1 V
Lead nullUp to 9.00 Ω
Buzzer limitAdjustable from 1 Ω to 200 Ω in 12 steps
Voltage
Range0.0 mV to 600 V AC and DC, True RMS
AccuracyDC ±2% ±2 digits; AC ±2% ±2 digits (>10 V TRMS sinusoidal, 15 Hz to 400 Hz)
Frequency15 Hz to 400 Hz, ±0.5% ±1 digit (15 Hz to 99.9 Hz)
Input impedance0.25 MΩ
General
Power6 x 1.5 V AA (IEC LR6) alkaline cells; 6 x 1.2 V NiMH rechargeable cells may be used
Battery life3000 insulation tests (5 s on / 55 s off at 1000 V into 1 MΩ)
Fuse1 x 500 mA (FF) 1000 V 32 x 6 mm ceramic HBC fuse, 30 kA minimum
SafetyEN 61010-1, 600 V phase to earth, CAT IV; EN 61557
IP ratingIP54
Operating temperature-10 °C to +55 °C, 90% RH at 40 °C max.
Storage temperature-25 °C to +70 °C
Maximum altitude2000 m
Dimensions228 x 108 x 63 mm
Weight1.75 kg (instrument and case)
Order code1004-735
Supplied with
ContentsRed / black silicone test leads with probes and clips; SP5 remote switch probe; 6 x AA alkaline batteries; Hard carry case; Calibration certificate

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.