Mean Well TDR-240-24 DIN Rail Power Supply 24 V, 10 A, 240 W, 3-Phase Input

Model number
TDR-240-24

Mean Well TDR-240-24, a DIN rail power supply for 3-phase input from the TDR-240 series for 340-550 V AC input, for control panels fed from a 3-phase supply.

Price and availability on request

Request a quote

Sent with the product details: Mean Well TDR-240-24 DIN Rail Power Supply 24 V, 10 A, 240 W, 3-Phase Input.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Three-Phase 340 ~ 550VAC wide range input (Dual phase operation possible)
  • 63mm slim width
  • Built-in passive PFC function compliance to BS EN/EN61000-3-2
  • High efficiency 92% and low power dissipation
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Full power between -30~+60°C
  • Built-in constant current limiting circuit
  • Can be installed on DIN rail TS-35/7.5 or 15
  • UL61010(industrial control equipment)approved
  • BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
  • DC OK relay contact
  • 3 years warranty

Specifications

Output
DC voltage24V
Rated current10A
Current range0 ~ 10A
Rated power240W
Ripple & noise (max.)100mVp-p
Voltage adj. range24 ~ 28V
Voltage tolerance±1.0%
Line regulation±0.5%
Load regulation±1.0%
Setup, rise time2000ms, 60ms/400VAC 1500ms, 60ms/500VAC at full load
Hold up time (typ.)20ms / 400VAC 40ms / 500VAC at full load
Input
Voltage rangeThree-Phase 340 ~ 550VAC (Dual phase operation possible in connecting L1,L3,FG or L2,L3,FG) or 480 ~ 780VDC
Frequency range47 ~ 63Hz
Power factor (typ.)92%
Efficiency (typ.)PF≧0.53/400VAC PF≧0.52/500VAC at full load
AC current (typ.)0.69A/400VAC 0.6A/500VAC
Inrush current (typ.)COLD START 50A
Leakage current<2mA/ 530VAC
Protection
OverloadProtection type : Constant current limiting, unit will hiccup after 3; 105 ~ 130% rated output power
Over voltage30 ~ 36V; Protection type : Hiccup mode, recovers automatically after fault condition is removed.
Over temperatureShut down o/p voltage, recovers automatically after temperature goes down
Function
DC OK relay contact ratings (max.)60VDC/0.3A, 30VDC/1A, 30VAC/0.5Aresistive load
Environment
Working temp.-30 ~ +70℃ (Refer to "Derating Curve")
Working humidity20 ~ 95% RH non-condensing
Storage temp., humidity-40 ~ +85℃, 10 ~ 95% RH non-condensing
Temp. coefficient±0.05%/℃ (0 ~ 60℃)
VibrationComponent:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X
Operating altitude5000 meters
Over voltage categoryⅢ;According to EN61558, EN50178, EN60664-1, EN62477-1, EN60204-1; altitude up to 2000 meters
Safety & EMC
Safety standardsUL61010-1, UL61010-2-201, BS EN/EN61558-1, BS EN/EN61558-2-16, BIS IS13252(Part1)(only for 24V), EAC TPTC 004 approved,; design refer toAS/NZS61558-1/-2-16
Withstand voltageI/P-O/P:4.87KVAC I/P-FG:2.4KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
Isolation resistanceI/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
Others
Dimension63*125.2*113.5mm (W*H*D)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.