Mean Well SDR-120-24 DIN Rail Power Supply 24 V, 5 A, 120 W
- Brand
- Mean Well
- Model number
- SDR-120-24
- Category
- DIN-Rail Power Supplies
Mean Well SDR-120-24, a DIN rail power supply from the SDR-120 series for 88-264 V AC input, up to 91% efficient, for control panels.
Price and availability on request
Key features
- High efficiency 91% and low power dissipation
- 150% peak load capability
- Built-in active PFC function, PF>0.93
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- 3 years warranty
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
- Built-in DC OK relay contact
- 100% full load burn-in test
Specifications
| DC voltage | 24V |
|---|---|
| Rated current | 5A |
| Current range | 0 ~ 5A |
| Rated power | 120W |
| Peak current | 7.5A |
| Peak power | 180W (3 sec.) |
| Ripple & noise (max.) | 100mVp-p |
| Voltage adj. range | 24 ~ 28V |
| Voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±1.0% |
| Setup, rise time | 1500ms, 60ms/230VAC 3000ms, 60ms/115VAC at full load |
| Hold up time (typ.) | 20ms/230VAC 20ms/115VAC at full load |
| Voltage range | 88 ~ 264VAC 124 ~ 370VDC |
|---|---|
| Frequency range | 47 ~ 63Hz |
| Power factor (typ.) | 0.93/230VAC 0.96/115VAC at full load |
| Efficiency (typ.) | 91% |
| AC current (typ.) | 1.4A/115VAC 0.7A/230VAC |
| Inrush current (typ.) | 35A/115VAC 70A/230VAC |
| Leakage current | <1mA / 240VAC |
| Overload | Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage; >150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down o/p voltage after 3 seconds |
|---|---|
| Over voltage | 29 ~ 33V; Protection type : Shut down o/p voltage, re-power on to recover |
| Over temperature | 95℃±5℃ (TSW) detect on heatsink of power switch; Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
| DC OK relay contact ratings (max.) | 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load |
|---|
| Working temp. | -25 ~ +70℃ (Refer to "Derating Curve") |
|---|---|
| Working humidity | 20 ~ 95% RH non-condensing |
| Storage temp., humidity | -40 ~ +85℃, 10 ~ 95% RH |
| Temp. coefficient | ±0.03%/℃ (0 ~ 50℃) |
| Vibration | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
| Safety standards | UL508, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004,BSMI CNS15598-1 approved;(meet BS EN/EN60204-1) |
|---|---|
| Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC |
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH |
| EMC emission | Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS15936 Class B |
| EMC immunity | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2),; BS EN/EN61204-3, heavy industry level, EAC TP TC 020, SEMI F47 approved |
| MTBF | 1764.6K hrs min. Telcordia SR-332 (Bellcore) ; 292.1K hrs min. MIL-HDBK-217F (25℃) |
|---|---|
| Dimension | 40*125.2*113.5mm (W*H*D) |
| Packing | 0.67Kg; 20pcs/14.4Kg/1.0CUFT |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.