Mean Well RSP-750-12 Enclosed Switching Power Supply 12 V, 62.5 A, 750 W
- Brand
- Mean Well
- Model number
- RSP-750-12
Mean Well RSP-750-12, an enclosed switching power supply from the RSP-750 series for 90-264 V AC input, up to 87% efficient, for machines, control panels and LED systems.
Price and availability on request
Key features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 92%
- Forced air cooling by built-in DC fan
- Output voltage and constant current level programmable
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5 years warranty
Specifications
| DC voltage | 12V |
|---|---|
| Rated current | 62.5A |
| Current range | 0 ~ 62.5A |
| Rated power | 750W |
| Ripple & noise (max.) | 150mVp-p |
| Voltage adj. range | 10 ~ 13.5V |
| Voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| Setup, rise time | 1000ms, 50ms at full load |
| Hold up time (typ.) | 16ms/230VAC 16ms/115VAC at full load |
| Voltage range | 90 ~ 264VAC 127 ~ 370VDC |
|---|---|
| Frequency range | 47 ~ 63Hz |
| Power factor (typ.) | 0.97/230VAC 0.98/115VAC at full load |
| Efficiency (typ.) | 87% |
| AC current (typ.) | 5V : 5.6A/115VAC 2.8A/230VAC 12V~48V : 8.2A/115VAC 3.9A/230VAC |
| Inrush current (typ.) | 25A/115VAC 40A/230VAC |
| Leakage current | <2.0mA/ 240VAC |
| Overload | 105 ~ 125% rated output power; Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|---|---|
| Over voltage | 13.8 ~ 16.8V; Protection type : Shut down o/p voltage, re-power on to recover |
| Over temperature | Shut down o/p voltage, recovers automatically after temperature goes down |
| Voltage programmable(PV) | Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual. |
|---|---|
| Constant current level programmable(PC) | Adjustment of constant current level is allowable to 40 ~ 110% of rated current. Please refer to the Function Manual. |
| Auxiliary power | 12V @ 0.1A; tolerance : ±10% |
| Remote ON-OFF control | Power on : short betweenRemote ON-OFF(pin13)&12V-AUX(pin14)on CN50 Power off : open betweenRemote ON-OFF(pin13)&12-AUX(pin14)on CN50 |
| DC OK signal | The TTLsignal out, power supply turn on = 0 ~ 1V ; power supply turn off = 3.3 ~ 5.6V |
| Working temp. | -30 ~ +70℃ (Refer to "Derating Curve") |
|---|---|
| Working humidity | 20 ~ 90% RH non-condensing |
| Storage temp., humidity | -40 ~ +85℃, 10 ~ 95% RH non-condensing |
| Temp. coefficient | ±0.03%/℃ (0 ~ 50℃) |
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety standards | UL62368-1, CSAC22.2 No. 62368-1,TUV BS EN/EN62368-1, CCC GB4943.1, BSMICNS15598-1, AS/NZS62368.1, EACTPTC 004,; BIS IS13252(Part1): 2010/IEC 60950-1:2005(exceptfor 48V)approved |
|---|---|
| Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
| MTBF | 336.9K hrs min. Telcordia SR-332 (Bellcore) ; 109.1K hrs min. MIL-HDBK-217F (25℃) |
|---|---|
| Dimension | 250*127*41mm (L*W*H) |
| Packing | 1.64Kg; 6pcs/10.8Kg/1.1CUFT |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.