Mean Well RSP-3000-12 Enclosed Switching Power Supply 12 V, 200 A, 2400 W
- Brand
- Mean Well
- Model number
- RSP-3000-12
Mean Well RSP-3000-12, an enclosed switching power supply from the RSP-3000 series for 180-264 V AC input, up to 87.5% efficient, for machines, control panels and LED systems.
Price and availability on request
Key features
- AC input 180~264VAC
- Built-in active PFC function
- High efficiency up to 91.5%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 9000W (2+1)
- Built-in remote ON-OFF control / remote sense / auxiliary power / power OK signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5 years warranty
Specifications
| DC voltage | 12V |
|---|---|
| Rated current | 200A |
| Current range | 0 ~ 200A |
| Rated power | 2400W |
| Ripple & noise (max.) | 150mVp-p |
| Voltage adj. range | 10.8 ~ 13.2V |
| Voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| Setup, rise time | 1000ms, 80ms at full load |
| Hold up time (typ.) | 10ms at full load |
| Voltage range | 180 ~ 264VAC 254 ~ 370VDC |
|---|---|
| Frequency range | 47 ~ 63Hz |
| Power factor (typ.) | 0.95/230VAC at full load |
| Efficiency (typ.) | 87.5% |
| AC current (typ.) | 20A/180VAC 16A/230VAC |
| Inrush current (typ.) | 60A/230VAC |
| Leakage current | <2.0mA / 240VAC |
| Overload | 100 ~ 112% rated output power; User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover |
|---|---|
| Over voltage | 13.8 ~ 16.8V; Protection type : Shut down o/p voltage, re-power on to recover |
| Over temperature | Shut down o/p voltage, recovers automatically after temperature goes down |
| Voltage programmable(PV) | 2.4 ~ 13.2V; Please refer to the Function Manual. |
|---|---|
| Current sharing | Up to 9000W or (2+1) units. Please refer to |
| Auxiliary power(AUX) | 12V@0.1A(Only for Remote ON/OFF control) |
| Remote ON-OFF control | Please refer to the Function Manual |
| Remote sense | Compensate voltage drop on the load wiring up to 0.25V. Please refer to the Function Manual. |
| Alarm signal output | Power OK signal. Please refer to the Function Manual |
| Working temp. | -20 ~ +70℃ (Refer to "Derating Curve") |
|---|---|
| Working humidity | 20 ~ 90% RH non-condensing |
| Storage temp., humidity | -40 ~ +85℃, 10 ~ 95% RH non-condensing |
| Temp. coefficient | ±0.05%/℃ (0 ~ 50℃) |
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety standards | UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, AS/NZS62368.1, IS13252(Part1)/IEC60950-1,; EAC TP TC 004 approved |
|---|---|
| Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
| Dimension | 278*177.8*63.5mm (L*W*H) |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.