Mean Well RSP-2000-24 Enclosed Switching Power Supply 24 V, 80 A, 1920 W
- Brand
- Mean Well
- Model number
- RSP-2000-24
Mean Well RSP-2000-24, an enclosed switching power supply from the RSP-2000 series for 90-264 V AC input, up to 90.5% efficient, for machines, control panels and LED systems.
Price and availability on request
Key features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 92%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 8000W (3+1)
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal / OTP alarm signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5 years warranty
Specifications
| DC voltage | 24V |
|---|---|
| Rated current | 80A |
| Current range | 0 ~ 80A |
| Rated power | 1920W |
| Ripple & noise (max.) | 200mVp-p |
| Voltage adj. range | 21 ~ 28V |
| Voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| Setup, rise time | 1500ms, 60ms/230VAC at full load |
| Hold up time (typ.) | 16ms/230VAC at 75% load 10ms/230VAC at full load |
| Voltage range | 90 ~ 264VAC 250 ~ 320VDC |
|---|---|
| Frequency range | 47 ~ 63Hz |
| Power factor (typ.) | 0.97/230VAC at full load |
| Efficiency (typ.) | 90.5% |
| AC current (typ.) | 16A/115VAC 10A/230VAC |
| Inrush current (typ.) | COLD START 50A |
| Leakage current | <2mA / 240VAC |
| Overload | 105 ~ 125% rated output power; Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover |
|---|---|
| Over voltage | 29.5 ~ 35V; Protection type : Shut down o/p voltage, re-power on to recover |
| Over temperature | Shut down o/p voltage, recovers automatically after temperature goes down |
| Voltage programmable(PV) | Adjustment of output voltage is allowable to 40 ~ 115% of nominal output voltage. Please refer to the Function Manual. |
|---|---|
| Current sharing | the Function Manual. |
| Auxiliary power | 5V @ 0.3A, 12V @ 0.8A |
| Remote ON-OFF control | By electrical signal or dry contact Power ON:open Power OFF:short. Please refer to the Function Manual. |
| Remote sense | Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual. |
| DC OK signal | The isolated TTL signal out. Please refer to the Function Manual. |
| Working temp. | -35 ~ +70℃ (Refer to "Derating Curve") |
|---|---|
| Working humidity | 20 ~ 90% RH non-condensing |
| Storage temp., humidity | -40 ~ +85℃, 10 ~ 95% RH non-condensing |
| Temp. coefficient | ±0.03%/℃ (0 ~ 50℃) |
| Vibration | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Safety standards | UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, AS/NZS62368.1,; BIS IS13252(Part1): 2010/IEC 60950-1:2005 (except 48V), EAC TP TC 004 approved |
|---|---|
| Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
| Dimension | 295*127*41mm (L*W*H) |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.