Mean Well RSP-1600-12 Enclosed Switching Power Supply 12 V, 125 A, 1500 W

Model number
RSP-1600-12

Mean Well RSP-1600-12, an enclosed switching power supply from the RSP-1600 series for 90-264 V AC input, up to 89% efficient, for machines, control panels and LED systems.

Price and availability on request

Request a quote

Sent with the product details: Mean Well RSP-1600-12 Enclosed Switching Power Supply 12 V, 125 A, 1500 W.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input / Full range
  • (Withstand 300VAC surge input for 5 seconds)
  • Built-in active PFC function
  • High efficiency up to 93%
  • Forced air cooling by built-in DC fan
  • Output voltage and constant current level programmable
  • Active current sharing up to 9600W (5+1)
  • Built-in remote ON-OFF control / remote sense /auxiliary power / DC OK signal / OTP alarm signal
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Optional PMBus or CANBus protocol
  • 5 years warranty

Specifications

Output
DC voltage12V
Rated current125A
Current range0 ~ 125A
Rated power1500W
Ripple & noise (max.)150mVp-p
Voltage adj. range11.5 ~ 15V
Voltage tolerance±1.0%
Line regulation±0.5%
Load regulation±0.5%
Setup, rise time1500ms, 60ms/230VAC at full load
Hold up time (typ.)16ms / 230VAC at 75% load 10ms / 230VAC at full load
Input
Voltage range90 ~ 264VAC 250 ~ 370VDC
Frequency range47 ~ 63Hz
Power factor (typ.)0.97/230VAC at full load
Efficiency (typ.)89%
AC current (typ.)14A/115VAC 8A/230VAC 15A/115VAC 8.5A/230VAC
Inrush current (typ.)COLD START 35A/230VAC
Leakage current<2mA / 230VAC
Protection
Overload105 ~ 115% rated current; Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover
Over voltage15.75 ~ 18.75V; Protection type : Shut down o/p voltage, re-power on to recover
Over temperatureProtection type : Shut down o/p voltage, recovers automatically after temperature goes down
Function
Voltage programmable(PV)Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V).; Please refer to the Function Manual.
Current programmable(PC)Adjustment of constant current level is allowable to 20 ~ 100% of rated current.; Please refer to the Function Manual.
Auxiliary power5V @ 0.3A, 12V @ 0.8A
Remote ON-OFF controlBy electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual
Remote senseCompensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual
Alarm signalIsolated signal output for T-alarm and DC OK
Environment
Working temp.-30 ~ +70℃ (Refer to "Derating Curve")
Working humidity20 ~ 90% RH non-condensing
Storage temp., humidity-40 ~ +85℃, 10 ~ 95% RH non-condensing
Temp. coefficient±0.03%/℃ (0 ~ 50℃)
Vibration10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Safety & EMC
Safety standardsUL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, AS/NZS62368.1, EAC TP TC 004 approved
Withstand voltageI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
Isolation resistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Others
Dimension300*85*41mm (L*W*H)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.