Mean Well RSDH-300-12 DC-DC Converter 250-1500 V DC In, 12 V, 20 A, 240 W, Railway, Ultra Wide Input

Model number
RSDH-300-12

Mean Well RSDH-300-12 DC-DC converter from the RSDH-300 series, taking 250-1500 V DC input and giving a regulated 12 V output at up to 87% efficiency. Built for railway and other vehicle supplies.

Price and availability on request

Request a quote

Sent with the product details: Mean Well RSDH-300-12 DC-DC Converter 250-1500 V DC In, 12 V, 20 A, 240 W, Railway, Ultra Wide Input.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 250~ 1500Vdc 6:1 ultra-wide input range
  • Withstand 1700Vdc surge input for 10 seconds
  • 4KVac I/O high isolation(Reinforced isolation)
  • Protections: Short circuit / Overload / Over voltage / Over temperature ·Industrial control system DC input under voltage / DC input reverse polarity
  • Fanless design, half encapsulated, cooling by free air convection
  • 40~+80°C ultra-wide operating temperature (>+55°C derating)
  • Over voltage categoryⅡ
  • Operating altitude up to 5000 meters
  • DC output voltage adjustable(12~15V, 24~29V, 30~36V, 48~58V)
  • 1U low profile 41mm
  • Half encapsulated
  • 3 years warranty

Specifications

Output
DC voltage12V
Rated current20A
Current range0 ~ 20A
Rated power240W
Ripple & noise (max.)120mVp-p
Voltage adj. range12 ~ 15V
Voltage tolerance±1.5%
Line regulation±0.5%
Load regulation±1.5%
External capacitance load (max.)8000μF
Input
Voltage range250 ~ 1500Vdc
Efficiency (typ.)87%; 88%; 86%
Inrush current (max.)COLD START 500A/1500Vdc 300A/800Vdc 120A/300Vdc
Protection
Overload105 ~ 135% rated output power; Protection type : Hiccup mode when output voltage<55%, recovers automatically after condition is removed;; Constant current limiting, recovers automatically after fault condition is removed within 55% ~ 100% rated output voltage
Over voltage16.5 ~ 21V; Protection type : Hiccup mode, recovers automatically after fault condition is removed
Over temperatureProtection type : Hiccup mode, recovers automatically after fault condition is removed
Reverse polarityBy internal Bridge Diode, no damage, recovers automatically after fault condition removed
DC input under voltage lockoutUnder voltage protection range: 200 ~ 225Vdc , Under voltage release range:225 ~ 246.5Vdc
Environment
Working temp.-40 ~ +80℃ (Refer to "Derating Curve")
Working humidity20 ~ 90% RH non-condensing
Storage temp., humidity-40 ~ +80℃, 10 ~ 95% RH non-condensing
Temp. coefficient±0.03%/℃ (0 ~ 55℃)
VibrationComponent: 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6
Operating altitude5000m
Over voltage categoryOVCⅡ 2000m;According to EN62109-1
Safety & EMC
Safety standardsUL1741, CSAC22.2 No.107.1-16 , IEC62109-1, BS EN/EN62109-1, EAC TPTC 004 approved
Withstand voltageI/P-O/P:4KVAC I/P-FG:3.75KVAC O/P-FG:2KVAC
Others
Dimension237*100*41mm (L*W*H)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.