Mean Well RSD-60L-24 DC-DC Converter 18-72 V DC In, 24 V, 2.5 A, 60 W, Railway
- Brand
- Mean Well
- Model number
- RSD-60L-24
- Category
- DC-DC Converters
Mean Well RSD-60L-24 DC-DC converter from the RSD-60 series, taking 18-72 V DC input and giving a regulated 24 V output at up to 91.5% efficiency. Built for railway and other vehicle supplies.
Price and availability on request
Key features
- Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
- Ultra compact and 1U low profile(25mm)
- 4:1 wide input range
- No minimum load required
- Protections: Short circuit / Overload / Over voltage / lnput reverse polarity
- 4000VDC l/O isolation (Reinforced isolation)
- Half encapsulated , cooling by free air convection
- 40~+70℃ wide working temperature
- Built-in constant current limiting circuit
- LED indicator for power on
- 3 years warranty
Specifications
| DC voltage | 24V |
|---|---|
| Rated current | 2.5A |
| Current range | 0 ~ 2.5A |
| Rated power | 60W |
| Ripple & noise (max.) | 50mVp-p |
| Voltage tolerance | ±2.0% |
| Line regulation | ±0.2% |
| Load regulation | ±0.2% |
| Setup, rise time | 100ms, 60ms at full load |
| Voltage range continuous | 18 ~ 72VDC |
|---|---|
| Efficiency (typ.) | 91.5% |
| DC current (typ.) | 2.1A/24VDC 3A/24VDC 0.95A/48VDC 1.5A/48VDC |
| Overload | 105 ~ 135% rated output power; Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|---|---|
| Over voltage | 27.6 ~ 32.4V; Protection type : Shut down o/p voltage, re-power on to recover |
| Working temp. | -40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate) |
|---|---|
| Working humidity | 5 ~ 95% RH non-condensing |
| Storage temp. | -40 ~ +85℃ |
| Temp. coefficient | ±0.03%/℃ (0 ~ 50℃) |
| Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373 |
| Operating altitude | 5000 meters |
| Safety standards | IEC 62368-1, UL62368-1, AS/NZS 62368-1, EACTPTC 004 approved, Design refer to BS EN/EN62368-1 |
|---|---|
| Withstand voltage | I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC |
| Railway standard | Compliance to BS EN/EN45545-2 for fire protection ; BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration,; BS EN/EN50121-3-2 for EMC |
| MTBF | 2738.8K hrs min. Telcordia SR-332 (Bellcore) ; 593.9K hrs min. MIL-HDBK-217F (25℃) |
|---|---|
| Dimension | 128*60*25mm (L*W*H) |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.