Mean Well RSD-500C-12 DC-DC Converter 33.6-67.2 V DC In, 12 V, 35 A, 420 W, Railway

Model number
RSD-500C-12

Mean Well RSD-500C-12 DC-DC converter from the RSD-500 series, taking 33.6-67.2 V DC input and giving a regulated 12 V output at up to 93% efficiency. Built for railway and other vehicle supplies.

Price and availability on request

Request a quote

Sent with the product details: Mean Well RSD-500C-12 DC-DC Converter 33.6-67.2 V DC In, 12 V, 35 A, 420 W, Railway.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • 1U low profile 41mm
  • 2:1 wide input range
  • Fanless design
  • , half encapsulated , cooling by free air convection
  • 40~+80℃ wide operating temperature
  • DC output adjustable
  • Protections: Short circuit / Overload / Over voltage / Over temperature / lnput reverse polarity/ lnput under voltage protection
  • 4KVdc l/O isolation(Reinforced isolation)
  • Operating additude up to 5000 meters(Note.5)
  • LED indicator for power on
  • 3 years warranty

Specifications

Output
DC voltage12V
Rated current35A
Current range0 ~ 35A
Rated power420W
Ripple & noise (max.)100mVp-p
Voltage adj. range12 ~ 14V
Voltage tolerance±1.0%
Line regulation±0.5%
Load regulation±1.0%
Setup, rise time500ms, 60ms
Input
Voltage continuous range33.6 ~ 67.2Vdc; 28.8 ~ 33.6Vdc
Efficiency (typ.)93%
DC current (typ.)11A@48Vdc
Inrush current (typ.)30A
Interruption of voltage supplyEN50155:2017-B/C/D type comply with S1 level (3ms)@ full load;; B/C type comply with S2 level (10ms)@ 70% load, D- type comply with S2 level (10ms) @ full load
Protection
OverloadConstant current limiting 105~135% rated output power with auto-recovery
Over voltage14.4 ~ 17.5V; Protection type : Shut down o/p voltage, re-power on to recover
Over temperatureShut down o/p voltage, re-power on to recover
Reverse polarityBy internal, MOSFET, no damage, recovers automatically after fault condition is removed
Under voltage lockout48Vin :Power; OFF≤33V
Environment
Working temp.-40 ~ +80℃ (Refer to "Derating Curve")
Working humidity5 ~ 95% RH non-condensing
Storage temp., humidity-40 ~ +85, 5 ~ 95% RH non-condensing
Temp. coefficient±0.03%/℃ (0 ~ 55℃)
VibrationComponent:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
Operating altitude5000 meters / OVCⅡ
Safety & EMC
Safety standardsUL62368-1, IEC 62368-1, AS/NZS 62368-1, EAC TPTC 004 approved, Design refer to BS EN/EN62368-1
Withstand voltageI/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:2.5KVdc
Others
MTBF834.7K hrs min. Telcordia SR-332 (Bellcore) ; 99.1K hrs min. MIL-HDBK-217F (25℃)