Mean Well RSD-100C-24 DC-DC Converter 33.6-62.4 V DC In, 24 V, 4.2 A, 100.8 W, Railway

Model number
RSD-100C-24

Mean Well RSD-100C-24 DC-DC converter from the RSD-100 series, taking 33.6-62.4 V DC input and giving a regulated 24 V output at up to 91% efficiency. Built for railway and other vehicle supplies.

Price and availability on request

Request a quote

Sent with the product details: Mean Well RSD-100C-24 DC-DC Converter 33.6-62.4 V DC In, 24 V, 4.2 A, 100.8 W, Railway.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • 2:1 wide input range
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity
  • 4000VDC I/O isolation
  • Cooling by free air convection
  • Half encapsulated
  • Built-in constant current limiting circuit
  • 1U low profile 36mm
  • All using 105℃ long life electrolytic capacitors
  • LED indicator for power on
  • 100% full load burn-in test
  • 3 years warranty

Specifications

Output
DC voltage24V
Rated current4.2A
Current range0 ~ 4.2A
Rated power100.8W
Ripple & noise (max.)150mVp-p
Voltage tolerance±2.0%
Line regulation±0.2%
Load regulation±1.0%
Setup, rise time800ms, 50ms at full load
Input
Voltage range (continuous; 1 sec.)33.6 ~ 62.4VDC; 28.8 ~ 67.2VDC
Efficiency (typ.)91%
DC current (typ.)2.4A/48V
Protection
Overload105 ~ 135% rated output power; Protection type : Constant current limiting, recovers automatically after fault condition is removed
Over voltage27.6 ~ 32.4V; Protection type : Shut down o/p voltage, re-power on to recover
Environment
Working temp.-40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ no derating with external base plate, TX class compliance
Working humidity5 ~ 95% RH non-condensing
Storage temp.-40 ~ +85℃
Temp. coefficient±0.03%/℃ (0 ~ 50℃)
Vibration10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
Operating altitude5000 meters
Safety & EMC
Safety standardsIEC 62368-1, UL62368-1, AS/NZS 62368-1, EACTPTC 004 approved, Design refer to BS EN/EN62368-1
Withstand voltageI/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
Isolation resistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC emissionCompliance to BS EN/EN55032 (CISPR32) Conduction Emission: ClassA, Radiation Emission: Class B, EAC TPTC 020
EMC immunityCompliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TPTC 020
Railway standardBS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC ; BS EN/EN45545-2 for fire protection
Others
MTBF2446.2K hrs min. Telcordia SR-332 (Bellcore) ; 254.2K hrs min. MIL-HDBK-217F (25℃)
Dimension161*68*36mm (L*W*H)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.