Mean Well NDR-240-24 DIN Rail Power Supply 24 V, 10 A, 240 W
- Brand
- Mean Well
- Model number
- NDR-240-24
- Category
- DIN-Rail Power Supplies
Mean Well NDR-240-24, a DIN rail power supply from the NDR-240 series for 90-264 V AC input, up to 88.5% efficient, for control panels.
Price and availability on request
Key features
- Universal AC input / Full range
- Built-in active PFC function
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Can be installed on DlN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
- 100% full load burn-in test
- 3 years warranty
Specifications
| DC voltage | 24V |
|---|---|
| Rated current | 10A |
| Current range | 0 ~ 10A |
| Rated power | 240W |
| Ripple & noise (max.) | 150mVp-p |
| Voltage adj. range | 24 ~ 28V |
| Voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±1.0% |
| Setup, rise time | 1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load |
| Hold up time (typ.) | 28ms/230VAC 22ms/115VAC at full load |
| Voltage range | 90 ~ 264VAC 127 ~ 370VDC |
|---|---|
| Frequency range | 47 ~ 63Hz |
| Power factor (typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load |
| Efficiency (typ.) | 88.5% |
| AC current (typ.) | 2.5A/115VAC 1.3A/230VAC |
| Inrush current (typ.) | 20A/115VAC 35A/230VAC |
| Leakage current | <1mA/ 240VAC |
| Overload | 105 ~ 130% rated output power; Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|---|---|
| Over voltage | 29 ~ 33V; Protection type : Shut down o/p voltage, re-power on to recover |
| Over temperature | Shut down o/p voltage, recovers automatically after temperature goes down |
| Working temp. | -20 ~ +70℃ (Refer to "Derating Curve") |
|---|---|
| Working humidity | 20 ~ 95% RH non-condensing |
| Storage temp., humidity | -40 ~ +85℃, 10 ~ 95% RH |
| Temp. coefficient | ±0.03%/℃ (0 ~ 50℃) |
| Vibration | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X |
| Safety standards | UL508, TUV BS EN/EN62368-1, EAC TPTC 004, BSMI CNS14336-1, BIS IS13252(Part1): 2010/IEC 60950-1:2005(NOTE 8) ,; KC K60950-1(for 48V only)approved; (meet BS EN/EN60204-1) |
|---|---|
| Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH |
| EMC emission | Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438,; KSC 9832(for 48V only) |
| EMC immunity | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2),; BS EN/EN61204-3, heavy industry level, EAC TP TC 020,KSC 9835(for 48V only) |
| MTBF | 1645.2K hrs min. Telcordia SR-332 (Bellcore) ; 230.2K hrs min. MIL-HDBK-217F (25℃) |
|---|---|
| Dimension | 63*125.2*113.5mm (W*H*D) |