Mean Well LRS-350-48 Enclosed Switching Power Supply 48 V, 7.3 A, 350.4 W
- Brand
- Mean Well
- Model number
- LRS-350-48
Mean Well LRS-350-48, an enclosed switching power supply from the LRS-350 series for 90-132 / 180-264 V AC input, up to 89% efficient, for machines, control panels and LED systems.
Price and availability on request
Key features
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling by built-in DC fan
- Built-in cooling Fan ON-OFF control
- 1U low profile
- Withstand 5G vibration test
- LED indicator for power on
- No load power consumption<0.75W
- 100% full load burn-in test
- High operating temperature up to 70℃
- Operating altitude up to 5000 meters (Note.8)
- High efficiency, long life and high reliability
- 3 years warranty
Specifications
| DC voltage | 48V |
|---|---|
| Rated current | 7.3A |
| Current range | 0 ~ 7.3A |
| Rated power | 350.4W |
| Ripple & noise (max.) | 200mVp-p |
| Voltage adj. range | 43.2 ~ 52.8V |
| Voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| Setup, rise time | 1500ms, 50ms/230VAC 1500ms,50ms/115VAC at full load |
| Hold up time (typ.) | 16ms/230VAC 12ms/115VAC at full load |
| Voltage range | 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC) |
|---|---|
| Frequency range | 47 ~ 63Hz |
| Efficiency (typ.) | 89% |
| AC current (typ.) | 6.8A/115VAC 3.4A/230VAC |
| Inrush current (typ.) | 60A/115VAC 60A/230VAC |
| Leakage current | <2mA / 240VAC |
| Over load | 110 ~ 140% rated output power; 3.3~36V Hiccup mode, recovers automatically after fault condition is removed.; 48V Shut down and latch off o/p voltage, re-power on to recover. |
|---|---|
| Over voltage | 55.2 ~ 64.8V; 3.3~36V Hiccup mode, recovers automatically after fault condition is removed.; 48V Shut down and latch off o/p voltage, re-power on to recover. |
| Over temperature | 3.3~36V Hiccup mode, recovers automatically after fault condition is removed.; 48V Shut down and latch off o/p voltage, re-power on to recover. |
| Fan ON/OFF control (typ.) | RTH3≧50℃ FAN ON, ≦40℃ FAN OFF |
|---|
| Working temp. | -25 ~ +70℃ (Refer to "Derating Curve") |
|---|---|
| Working humidity | 20 ~ 90% RH non-condensing |
| Storage temp., humidity | -40 ~ +85℃, 10 ~ 95% RH |
| Temp. coefficient | ±0.03%/℃ (0 ~ 50℃) |
| Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
| Over voltage category | Ⅲ: According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters |
| Safety standards | IEC/UL 62368-1,BSMI CNS15598-1,EAC TP TC 004,KC62368-1(for LRS-350-12/24 only),GB 4943.1,; BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 11),BS EN/EN61558-1, BS EN61558-2-16; Designed by AS/NZS 61558.1/2.16, AS/NZS 62368.1,BS EN/EN62368-1 |
|---|---|
| Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH |
| EMC emission | Compliance to BSMI CNS15936, EAC TP TC 020,KSC9832,KSC9835(for LRS-350-12/24 only) |
| EMC immunity | Compliance to BS EN/EN55035, EAC TP TC 020,KSC9832,KSC9835(for LRS-350-12/24 only) |
| MTBF | 2099.9K hrs min. Telcordia SR-332 (Bellcore) ; 328.6Khrs min. MIL-HDBK-217F (25℃) |
|---|---|
| Dimension | 215*115*30mm (L*W*H) |
| Packing | 0.76Kg; 15pcs/12.4Kg/0.67CUFT |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.