Mean Well LRS-200N2-12 Enclosed Power Supply 12 V, 17 A, 204 W, High Peak

Model number
LRS-200N2-12

Mean Well LRS-200N2-12, a high peak power enclosed power supply from the LRS-200N2 series for 90-132 / 180-264 V AC input, up to 87.5% efficient, for machines, control panels and LED systems.

Price and availability on request

Request a quote

Sent with the product details: Mean Well LRS-200N2-12 Enclosed Power Supply 12 V, 17 A, 204 W, High Peak.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 second
  • Up to 200% peak power capability
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Compliance to IEC/BS EN/EN61558-1 and 62368-1
  • Withstand 5G vibration test
  • LED indicator for power on
  • No load power consumption<1W
  • Over voltage category Ⅲ(OVC Ⅲ)
  • High operating temperature up to 70℃
  • Operating altitude up to 2000 meters
  • High efficiency, long life and high reliability
  • 3 years warranty

Specifications

Output
DC voltage12V
Rated current17A
Current range0 ~ 17A
Rated power204W
Ripple & noise (max.)150mVp-p
Voltage adj. range10.2 ~ 13.8V
Voltage tolerance±1.5%
Line regulation±0.5%
Load regulation±1.0%
Setup, rise time1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load
Hold up time (typ.)16ms/230VAC 12ms/115VAC at full load
Input
Voltage range90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC)
Frequency range47 ~ 63Hz
Efficiency (typ.)87.5%
AC current (typ.)4.1A/115VAC 2.4A/230VAC
Inrush current (typ.)COLD STAR 60A/115VAC 60A/230VAC
Leakage current<2mA / 240VAC
Protection
Over loadOutput power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover; Ouput power >200% rated, hiccup mode, recovers automatically after fault condition is removed
Over voltage13.8 ~ 16.2V; Shut down and latch off o/p voltage, re-power on to recover.
Over temperatureShut down and latch off o/p voltage, re-power on to recover.
Environment
Working temp.-25 ~ +70℃ (Refer to "Derating Curve")
Working humidity20 ~ 90% RH non-condensing
Storage temp., humidity-40 ~ +85℃, 10 ~ 95% RH
Temp. coefficient±0.03%/℃ (0 ~ 50℃)
Vibration10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Safety & EMC
Withstand voltageI/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation resistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC emissionCompliance to BSMI CNS15936, EAC TP TC 020
EMC immunityCompliance to BS EN/EN55035, EAC TP TC 020
Others
MTBF2089.1K hrs min. Telcordia SR-332 (Bellcore) ; 243.6Khrs min. MIL-HDBK-217F (25℃)
Dimension215*115*30mm (L*W*H)
Packing0.66Kg; 15pcs/10.7Kg/0.67CUFT

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.