Mean Well LRS-100N2-36 Enclosed Power Supply 36 V, 2.8 A, 100.8 W, High Peak
- Brand
- Mean Well
- Model number
- LRS-100N2-36
Mean Well LRS-100N2-36, a high peak power enclosed power supply from the LRS-100N2 series for 85-264 V AC input, up to 90% efficient, for machines, control panels and LED systems.
Price and availability on request
Key features
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 second
- Up to 200% peak power capability
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Miniature size and 1U low profile
- Compliance to IEC/BS EN/EN61558-1 and 62368-1
- Operating altitude up to 4000 meters
- Withstand 5G vibration test
- LED indicator for power on
- No load power consumption<0.5W
- Over voltage category Ⅲ(OVC Ⅲ)
- High operating temperature up to 70℃
- High efficiency, long life and high reliability
- 3 years warranty
Specifications
| DC voltage | 36V |
|---|---|
| Rated current | 2.8A |
| Current range | 0 ~ 2.8A |
| Rated power | 100.8W |
| Ripple & noise (max.) | 200mVp-p |
| Voltage adj. range | 32.4 ~ 39.6V |
| Voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| Setup, rise time | 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load |
| Hold up time (typ.) | 55ms/230VAC 10ms/115VAC at full load |
| Voltage range | 85 ~ 264VAC 120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) |
|---|---|
| Frequency range | 47 ~ 63Hz |
| Efficiency (typ.) | 90% |
| AC current (typ.) | 2.1A/115VAC 1.2A/230VAC |
| Inrush current (typ.) | COLD START 55A/230VAC |
| Leakage current | <0.75mA / 240VAC |
| Over load | Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover; Ouput power >200% rated, hiccup mode, recovers automatically after fault condition is removed |
|---|---|
| Over voltage | 41.4 ~ 48.6V; Protection type : Shut down o/p voltage, re-power on to recover |
| Working temp. | -30 ~ +70℃ (Refer to "Derating Curve") |
|---|---|
| Working humidity | 20 ~ 90% RH non-condensing |
| Storage temp., humidity | -40 ~ +85℃, 10 ~ 95% RH non-condensing |
| Temp. coefficient | ±0.03%/℃ (0 ~ 50℃) |
| Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
| Over voltage category | Ⅲ: IEC/BS EN/EN61558-1/-2-16 4000 meters approved, Compliance to BS EN/EN60664-1, BS EN/EN62477-1,; altitude up to 4000 meters; Ⅱ: UL 62368-1, TUV BS EN/EN62368-1, IEC62368-1 approved, altitude up to 5000 meters;; TUV BS EN/EN60335-1, IEC 60335-1 approved, altitude up to 4000 meters |
| Safety standards | CB: IEC62368-1, IEC61558-1, IEC61558-2-16, IEC60335-1; TUV: BS EN/EN62368-1, BS EN/EN61558-1/-2-16, BS EN/EN60335-1; UL: UL62368-1; CQC: GB4943.1; BSMI: CNS15598-1; EAC: TP TC 004, S/NZS62368.1(by CB); BIS: IS 13252(Part1):2010/IEC 60950-1:2005(except for 48V); RCM: Designed refer to AS/NZS 61558.1/2.16, AS/NZS62368.1 |
|---|---|
| Withstand voltage | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC |
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
| EMC emission | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤80%; Load), BS EN/EN61000-3-3, BSMI CNS15936, EAC TP TC 020 |
| EMC immunity | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,; heavy industry level, EAC TP TC 020 |
| MTBF | 2802.6K hrs min. Telcordia SR-332 (Bellcore) ; 536.6Khrs min. MIL-HDBK-217F (25℃) |
|---|---|
| Dimension | 129*97*30mm (L*W*H) |
| Packing | 0.35Kg ; 40pcs/15Kg/0.92CUFT |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.