Mean Well LRS-100N2-24 Enclosed Power Supply 24 V, 4.2 A, 100.8 W, High Peak

Model number
LRS-100N2-24

Mean Well LRS-100N2-24, a high peak power enclosed power supply from the LRS-100N2 series for 85-264 V AC input, up to 90% efficient, for machines, control panels and LED systems.

Price and availability on request

Request a quote

Sent with the product details: Mean Well LRS-100N2-24 Enclosed Power Supply 24 V, 4.2 A, 100.8 W, High Peak.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 second
  • Up to 200% peak power capability
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Miniature size and 1U low profile
  • Compliance to IEC/BS EN/EN61558-1 and 62368-1
  • Operating altitude up to 4000 meters
  • Withstand 5G vibration test
  • LED indicator for power on
  • No load power consumption<0.5W
  • Over voltage category Ⅲ(OVC Ⅲ)
  • High operating temperature up to 70℃
  • High efficiency, long life and high reliability
  • 3 years warranty

Specifications

Output
DC voltage24V
Rated current4.2A
Current range0 ~ 4.2A
Rated power100.8W
Ripple & noise (max.)150mVp-p
Voltage adj. range21.6 ~ 28.8V
Voltage tolerance±1.0%
Line regulation±0.5%
Load regulation±0.5%
Setup, rise time500ms, 30ms/230VAC 500ms,30ms/115VAC at full load
Hold up time (typ.)55ms/230VAC 10ms/115VAC at full load
Input
Voltage range85 ~ 264VAC 120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
Frequency range47 ~ 63Hz
Efficiency (typ.)90%
AC current (typ.)2.1A/115VAC 1.2A/230VAC
Inrush current (typ.)COLD START 55A/230VAC
Leakage current<0.75mA / 240VAC
Protection
Over loadOutput power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover; Ouput power >200% rated, hiccup mode, recovers automatically after fault condition is removed
Over voltage28.8 ~ 33.6V; Protection type : Shut down o/p voltage, re-power on to recover
Environment
Working temp.-30 ~ +70℃ (Refer to "Derating Curve")
Working humidity20 ~ 90% RH non-condensing
Storage temp., humidity-40 ~ +85℃, 10 ~ 95% RH non-condensing
Temp. coefficient±0.03%/℃ (0 ~ 50℃)
Vibration10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Over voltage categoryⅢ: IEC/BS EN/EN61558-1/-2-16 4000 meters approved, Compliance to BS EN/EN60664-1, BS EN/EN62477-1,; altitude up to 4000 meters; Ⅱ: UL 62368-1, TUV BS EN/EN62368-1, IEC62368-1 approved, altitude up to 5000 meters;; TUV BS EN/EN60335-1, IEC 60335-1 approved, altitude up to 4000 meters
Safety & EMC
Safety standardsCB: IEC62368-1, IEC61558-1, IEC61558-2-16, IEC60335-1; TUV: BS EN/EN62368-1, BS EN/EN61558-1/-2-16, BS EN/EN60335-1; UL: UL62368-1; CQC: GB4943.1; BSMI: CNS15598-1; EAC: TP TC 004, S/NZS62368.1(by CB); BIS: IS 13252(Part1):2010/IEC 60950-1:2005(except for 48V); RCM: Designed refer to AS/NZS 61558.1/2.16, AS/NZS62368.1
Withstand voltageI/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
Isolation resistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC emissionCompliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤80%; Load), BS EN/EN61000-3-3, BSMI CNS15936, EAC TP TC 020
EMC immunityCompliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,; heavy industry level, EAC TP TC 020
Others
MTBF2802.6K hrs min. Telcordia SR-332 (Bellcore) ; 536.6Khrs min. MIL-HDBK-217F (25℃)
Dimension129*97*30mm (L*W*H)
Packing0.35Kg ; 40pcs/15Kg/0.92CUFT

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.