Mean Well DDRH-60-24 DC-DC Converter 150-1500 V DC In, 24 V, 2.5 A, 60 W, DIN Rail, Ultra Wide Input
- Brand
- Mean Well
- Model number
- DDRH-60-24
- Category
- DC-DC Converters
Mean Well DDRH-60-24 DC-DC converter from the DDRH-60 series, taking 150-1500 V DC input and giving a regulated 24 V output at up to 86% efficiency. Made for solar and battery systems with very high DC voltages.
Price and availability on request
Key features
- 150~1500Vdc 10:1 ultra-wide input range
- 57mm slim width
- 4KVac l/O high isolation(Reinforced isolation)
- Protections: Short circuit / Overload / Over voltage / DC input under voltage / DC input reverse Polarity
- 3 years warranty
- DC OK relay contact
- DC output voltage adjustable(+20%)
- Fanless design, fully encapsulated, cooling by free air convection
- Can be installed on DlN rail TS-35/7.5 or 15 (DR-Type)
- 30~+80°C ultra-wide operating temperature (>+55°C derating)
- Operating altitude up to 5000 meters
- Full encapsulated
- Over voltage categoryⅡ
Specifications
| DC voltage | 24V |
|---|---|
| Rated current | 2.5A |
| Current range | 0 ~ 2.5A |
| Rated power | 60W |
| Ripple & noise (max.) | 150mVp-p |
| Voltage adj. range | 24 ~ 29V |
| Voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| External capacitance load (max.) | 2500μF |
| Voltage range | 150 ~ 1500Vdc |
|---|---|
| Efficiency (typ.) | 86%; 87%; 84% |
| Inrush current (max.) | COLD START 120A/1500Vdc 80A/800Vdc 30A/150Vdc |
| Overload | 105 ~ 135% rated output power; Protection type : Hiccup up mode when output voltage<55%, recovers automatically after condition is removed;; Constant current limiting, recovers automatically after fault condition is removed within 55% ~ 100% rated output voltage |
|---|---|
| Over voltage | 30 ~ 38V; Protection type : Hiccup up mode, recovers automatically after fault condition is removed |
| Over temperature | Protection type : Hiccup up mode, recovers automatically after fault condition is removed |
| Reverse polarity | By internal Bridge Diode, no damage, recovers automatically after fault condition removed |
| DC input under voltage lockout | Under voltage protection range:120 ~ 130Vdc , Under voltage release range:130 ~ 146.5Vdc |
| DC OK signal | Relay contact rating(max.) : 30V / 1Aresistive |
|---|
| Working temp. | -30 ~ +80℃ (Refer to "Derating Curve") |
|---|---|
| Working humidity | 20 ~ 90% RH non-condensing |
| Storage temp., humidity | -40 ~ +80℃, 10 ~ 95% RH non-condensing |
| Temp. coefficient | ±0.03%/℃ (0 ~ 55℃) |
| Vibration | Component: 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6 |
| Operating altitude | 5000 meters /OVCⅡ |
| Over voltage category | Ⅱ;According to EN62109-1; altitude up to 5000 meters |
| Safety standards | UL1741, CSAC22.2 No.107.1-16 , IEC62109-1(LVD) , EAC TPTC 004 approved |
|---|---|
| Withstand voltage | I/P-O/P:4KVAC O/P-DC OK:0.5KVAC |
| Dimension | 57*93.5*105mm (W*H*D) |
|---|