Mean Well DDR-120D-12 DC-DC Converter 67.2-154 V DC In, 12 V, 10 A, 120 W, DIN Rail

Model number
DDR-120D-12

Mean Well DDR-120D-12 DC-DC converter from the DDR-120 series, taking 67.2-154 V DC input and giving a regulated 12 V output at up to 89.5% efficiency. Snaps onto a DIN rail.

Price and availability on request

Request a quote

Sent with the product details: Mean Well DDR-120D-12 DC-DC Converter 67.2-154 V DC In, 12 V, 10 A, 120 W, DIN Rail.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Width only 32mm
  • 2:1 wide input range
  • 40~+70℃ wide working temperature
  • 150% peak load capability
  • DC output adjustable
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity / Input under voltage protection
  • 4KVdc I/O isolation(Reinforced isolation)
  • 3 years warranty

Specifications

Output
DC voltage12V
Rated current10A
Current range0 ~ 10A
Rated power120W
Peak current15A
Peak power180W (3sec.)
Ripple & noise (max.)50mVp-p
Voltage adj. range9 ~ 14V
Voltage tolerance±1.0%
Line regulation±0.5%
Load regulation±1.0%
Setup, rise time500ms, 60ms @110Vdc
Input
Voltage range67.2 ~ 154Vdc
Efficiency (typ.)89.5%
DC current (typ.)1.3A @110Vdc
Inrush current (typ.)5A @110Vdc
Protection
Over voltage14.4 ~ 16.8V; Protection type : Shut down o/p voltage, re-power on to recover
Reverse polarityBy internal MOSFET, no damage, recovers automatically after fault condition removed
Under voltage lockout110Vin (D - type):Power ON≥67.2V , OFF≤65V
Environment
Working temp.-40 ~ +70℃ (Refer to "Derating Curve")
Working humidity5 ~ 95% RH non-condensing
Storage temp., humidity-40 ~ +85℃, 5 ~ 95% RH non-condensing
Temp. coefficient±0.03%/℃ (0 ~ 55℃)
VibrationComponent:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
Operating altitude5000 meters
Safety & EMC
Safety standardsIEC 62368-1, UL 62368-1, EAC TP TC 004, AS/NZS 62368.1 approved; Design refer to UL508
Withstand voltageI/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:2.5KVdc
Railway standardCompliance to BS EN/EN45545-2 for fire protection ; Meet BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration,; BS EN/EN50121-3-2 for EMC
Others
MTBF1769.5K hrs min. Telcordia SR-332 (Bellcore) ; 214.5K hrs min. MIL-HDBK-217F (25℃)
Dimension32*125.2*102mm (W*H*D)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.