Mastech MS2101 AC/DC Clamp Meter, 1000 A, 4000 Count
- Brand
- Mastech
- Model number
- MS2101
- Category
- AC/DC Clamp Meters
AC/DC clamp meter with 42 mm jaw and 4000 counts. AC and DC current to 1000 A, voltage to 1000 V, resistance to 40 MΩ, capacitance, frequency, duty cycle and K-type temperature. CAT III 600 V, CAT II 1000 V.
Price and availability on request
We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.
Several models? Add each to your enquiry list and send them as one enquiry.
Key features
- 4000 counts, auto and manual ranging
- AC and DC current 400 A and 1000 A, jaw opening 42 mm
- DC voltage to 1000 V, AC voltage to 750 V
- Resistance to 40 MΩ, capacitance to 100 µF, frequency to 100 kHz, duty cycle
- Temperature to 750 °C (K-type)
- Relative (zero) measurement, data hold, auto power off
Specifications
| Safety rating | CAT III 600 V, CAT II 1000 V |
|---|---|
| Functions | Relative measurement, data hold, peak measurement, diode test (open voltage 2.2 V), continuity buzzer, auto power off |
| Supplied with | Test leads, K-type thermocouple, carry bag, battery, user manual |
| Certification | RoHS, CE |
| Display counts | 4000 |
|---|
| Jaw opening | 42 mm (1.7") |
|---|---|
| Size | 250 × 99 × 43 mm |
| AC and DC current | 400 A / 1000 A; ±(3.0% + 3) |
|---|---|
| DC voltage | 400 mV to 1000 V; ±(0.7% + 1) up to 400 V, ±(0.8% + 3) at 1000 V |
| AC voltage | 4 V to 750 V; ±(0.8% + 5) up to 400 V, ±(1.0% + 10) at 750 V |
| Resistance | 400 Ω to 40 MΩ; ±(1.2% + 1) up to 4 MΩ, ±(2.0% + 3) at 40 MΩ |
| Capacitance | 4 nF to 100 µF; ±(4.0% + 10) |
| Frequency | Up to 100 kHz |
| Temperature | -40 °C to 750 °C (K-type) |
| Power supply | 1 × 9 V (6F22) |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details