Mastech MS2001C AC Digital Clamp Meter, 1000 A with Temperature

Brand
Mastech
Model number
MS2001C

AC clamp meter with 42 mm jaw, 2000 counts and K-type temperature measurement to 750 °C. AC current to 1000 A, DC volts to 1000 V, AC volts to 750 V, resistance to 2000 Ω. CAT III 600 V.

Price and availability on request

We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.

Several models? Add each to your enquiry list and send them as one enquiry.

Request a quote

Sent with the product details: Mastech MS2001C AC Digital Clamp Meter, 1000 A with Temperature.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • 2000 counts, 42 mm jaw opening
  • AC current 20 A, 200 A and 1000 A ranges
  • DC voltage 1000 V, AC voltage 750 V
  • Resistance 200 Ω and 2000 Ω
  • Temperature -40 °C to 750 °C with K-type thermocouple
  • Continuity buzzer, data hold, backlight

Specifications

General
Safety ratingCAT III 600 V, CAT II 1000 V
FunctionsContinuity buzzer, data hold, peak measurement, backlight
Supplied withTest leads, K-type thermocouple, carry bag, battery, user manual
CertificationRoHS, CE
Display
Display counts2000
Physical
Jaw opening42 mm (1.7")
Size250 × 99 × 43 mm
Measurement
AC current20 A / 200 A / 1000 A; ±⁠(2.0% + 5) on 20 A and 200 A, ±⁠(2.0% + 7) on 1000 A
DC voltage1000 V; ±⁠(1.0% + 2)
AC voltage750 V; ±⁠(1.0% + 5)
Resistance200 Ω / 2000 Ω; ±⁠(1.0% + 3)
Temperature-40 °C to 750 °C (K-type); ±⁠(1.0% + 3) from 1 to 400 °C, ±⁠(1.0% + 5) from 401 to 750 °C
Electrical
Power supply1 × 9 V (6F22)