Lutron YK-2005WA Multi-parameter Water Meter with Data Logger
- Brand
- Lutron
- Model number
- YK-2005WA
- Category
- Water Quality Meters
Multi-purpose meter for pH, ORP, conductivity, TDS and dissolved oxygen with ATC and a real-time data logger for 16,000 readings.
Price and availability on request
Key features
- One meter for multi purpose operation: PH/ORP, DO, CD/TDS METER
- pH: 0 to 14.00 pH, ORP: ± 1999 mV.
- Conductivity: 200 uS/2 mS/20 mS/200 mS.
- Dissolved oxygen: 0 to 20.0 mg/L.
- ATC (automatic temperature compensation).
- Real time data logger (record year, month, date, hour, minute, second), 16,000 data logger.
- Max., Min., Data hold.
- RS-232 computer interface
- Optional electrode: pH, ORP, CD/TDS, DO, ATC probe.
- Jumbo LCD display.
- DC 1.5V (UM-3, AA) x 4 PCs or DC 9V adapter in.
- Size: 203 x 76 x 38 mm.
Specifications
| Display | LCD size : 58 mm x 34 mm. |
|---|---|
| Measurement | PH/ORP; Conductivity/TDS(Total Dissolved Solids); Dissolved Oxygen |
| Data Hold | Freeze the display reading. |
| Memory Recall | Maximum & Minimum value. |
| Sampling Time | Approx. 1 second. |
| Circuit | Custom one-chip of microprocessor LSI circuit. |
| Power off | Auto shut off saves battery life or manual off by push Button.; @Can default auto power or manual power off.; @When default auto power function, power will off automatically after 10 MIN, if no Button be pressed. |
| Operating Temp. | 0 to 50 °C. - Main instrument. |
| Operating Humidity | Less than 80% R.H. |
| Power Supply | DC 1,5 V battery ( UM3 ) x 4 PCs, ( Heavy duty type ).; DC 9V adapter input. @ AC/DC power adapter is optional. |
| Dimension | 203 x 76 x 38 mm |
| Weight | 365 g/ 0.8 LB. @ Battery is included. |
| Datalogger Sampling Time Setting range | 2 sec to 8 hour 59 min. 59 sec.; @ Auto datalogger |
| Power Current | Operatiron : Approx. DC 28 mA; Clock ( power off ) : Approx. DC 1 uA. |
| Data Output | RS 232 PC serial interface. |
| Supplied with | *Instruction manual; *Hard carrying case : CA-06 |
|---|---|
| Optional | * PH electrode : PE-03, PE-11, PE-06HDA, PE-04HDA, PE-03K7; * ATC ( Automatic Temperature Probe ) : TP-07; * pH 7 buffer solution : PH-07; * pH 4 buffer solution : PH-04; * Conductivity probe : CDPB-03; * 1.413 mS Conductivity Standard Solution : CD-14; * Oxygen probe : OXPB-11; * Spare Probe head with Diaphragm set : OXHD-04; * Probe-filling Electrolyte : OXEL-03; * AC to DC 9V adapter.; * RS232 cable, UPCB-02.; * USB cable, USB-01; * Data Acquisition software, SW-E816. |
| Optional (cont.) | * Data Logger software, SW-DL2005. |
| pH | 0 to 14.00 pH |
|---|---|
| ORP | ± 1999 mV |
| Conductivity | 0 to 200 µS, 0.2 to 2.000 mS, 2 to 20.00 mS, 20 to 200.0 mS |
| TDS | 0 to 132 PPM, 132 to 1,320 PPM, 1,320 to 13,200 PPM, 13,200 to 132,000 PPM |
| Dissolved Oxygen | 0 to 20.0 mg/L |
| pH | 0.01 pH |
|---|---|
| Conductivity | 0.1 µS, 0.001 mS, 0.01 mS, 0.1 mS |
| TDS | 0.1 PPM, 1 PPM, 10 PPM, 100 PPM |
| Dissolved Oxygen | 0.1 mg/L |
| Temperature | 0.1°C / 0.1°F |
| pH | ±0.02 pH + 2d |
|---|---|
| ORP | ±0.5% + 2d |
| Dissolved Oxygen | ±0.4 mg/L |
| Temperature | ±0.8°C / ±1.5°F |
| Power Supply | DC 1.5V battery (UM-3, AA) x 4 PCs or DC 9V adapter |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.