Lutron WBGT-2010SD WBGT Heat Index Meter, SD Logger

Brand
Lutron
Model number
WBGT-2010SD

Heat stress meter for indoor/outdoor WBGT using a Pt globe sensor, with humidity, adjustable alarm and SD card data logging.

Price and availability on request

Request a quote

Sent with the product details: Lutron WBGT-2010SD WBGT Heat Index Meter, SD Logger.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Introduction: WBGT (wet-bulb globe temperature) was developed as a monitoring basis at US military training camps and became widespread for the use in workplaces and sports situation It is suggested in the international standard ISO 7243, OSHA (US Occupation Safety), Japan Society for Occupational Health and the SMA (Sports Medicine Australia) in establishing the permissible heat exposure limits in health, sports or other physical activities.
  • Measurement: WBGT value (Indoor/Outdoor Wet bulb globe temperature), Black globe temperature, Humidity, Air temperature, Wet bulb temperature, Dew point Temp..
  • Adjustable WBGT alarm setting, if the WBGT value over the alarm threshold, the buzzer will sound along with the flashing Display.
  • Using to control and monitor of physical activity in hot environment to limit the danger of heat related injuries.
  • Globe temperature measurement use the Pt sensor, high accuracy.
  • Fast humidity measuring response time.
  • Direct measurement of the radiation effect with a brass black ball in 75 mm dia.
  • Sensor protecting mechanism.
  • Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder, sampling time set from 1 second to 3600 seconds.
  • Manual datalogger is available (set the sampling time to 0), during execute the manual datalogger function, it can set the different position (location) No. (position 1 to position 99).
  • Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer, it can down load the all the measured value with the time information (year/month/date/ hour/minute/second) to the Excel directly, then user can make the further data or graphic analysis by themselves.
  • SD card capacity: 1 GB to 16 GB.
  • LCD with green light backlight, easy reading.
  • Can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Microcomputer circuit, high accuracy.
  • Power by UM3/AA (1.5 V) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.

Specifications

Specifications
CircuitCustom one-chip of microprocessor LSI; circuit.
DisplayLCD size : 52 mm x 38 mm; LCD with green backlight ( ON/OFF ).
MeasurementWet bulb globe temperature ( WBGT ); @ Indoor/Outdoor; Black globe temperature ( TG ); Air temperature ( TA ); Wet bulb temperature ( WB ); Humidity; Dew point temperature
WBGT formulaIndoor/Outdoor and no sun : WBGT = ( 0.7 x WB ) + ( 0.3 x TG ); Outdoor and full sun : WBGT = ( 0.7 x WB ) + ( 0.2 x TG ) + ( 0.1 x TA )
WBGT alarm settingAdjustable WBGT alarm setting, if the WBGT value over the alarm threshold, the buzzer will sound along with the flashing Display.
Datalogger Sampling Time Setting rangeAuto 1 second to 3600 seconds; @ Sampling time can set to 1 second, but memory data may loss; Manual Push the data logger button once will save data one time.; @ Set the sampling time to second; @ Manual mode, can also select the 1 to 99 position ( Location ) no.
Data error no.0.1% of total saved data max.
Memory CardSD memory card. 1 GB to 16 GB
Advanced setting* Set clock time ( Year/Month/Date, Hour/Minute/ Second ); * Set WBGT alarm value; * Decimal point of SD card setting; * Auto power OFF management; * Set beep Sound ON/OFF; * Select the temperature unit to °C or °F.; * Set sampling time; * SD memory card Format
Data HoldFreeze the display reading.
Memory RecallMaximum & Minimum value.
Sampling Time of DisplayApprox. 1 second.
Data OutputRS 232/USB PC computer interface.; * Connect the optional RS232 cable Dew Point Temp.; UPCB-02 will get the RS232 plug.; * Connect the optional USB cable; USB-01 will get the USB plug
Operating Temperature0 to 50 °C
Operating HumidityLess than 85% R.H.
Power Supply* AAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.; * ADC 9V adapter input. ( AC/DC poweradapter is optional ).
Power CurrentNormal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 5 mA.; When SD card save the data but and LCD Backlight is OFF) : Approx. DC 25 mA.; * AIf LCD backlight on, the power consumption will increase approx. 11mA.
Weight489 g/1.08 LB.
DimensionMeter 177 x 68 x 45 mm; Black brass ball (7.0 x 2.7x 1.9 inch)Round, 75 mm dia
Accessories
Supplied with* Instruction manual:1 PC; * Black brass ball ( with sensor :1 PC; * Soft carrying case, CA-05B: 1 PC
Optional* SD Card ( 2 GB ); * AC to DC 9V adapter.; * USB cable, USB-01.; * RS232 cable, UPCB-02.; * Data Acquisition software,SW-U801-WIN.; * Hard carrying case, CA-08; Size : 370 x 310 x 115 mm.
Measurement Functions
Indoor0 to 59°C / 32 to 138°F
Outdoor0 to 56°C / 32 to 132°F
Indoor±1°C (15 to 59°C) / ±1.5°C (Others)
Outdoor±2°C (15 to 56°C) / ±2.7°C (Others)
Range0 to 80°C / 32 to 176°F
Accuracy±0.6°C (15 to 40°C) / ±1.1°F
Range5% to 95% RH
Range-25.3 to 48.9°C / -13.5 to 120.1°F
Range0 to 50°C / 32 to 122°F
Accuracy±0.8°C / ±1.5°F
Range-21.6 to 50.0°C / -6.9 to 122.0°F

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.