Lutron VB-8100 Vibration Meter, Acceleration / Velocity / Displacement, RS232

Brand
Lutron
Model number
VB-8100

Vibration meter for acceleration, velocity and displacement from 10 Hz to 1 kHz to ISO 2954, with RMS, peak and max hold and RS232/USB output.

Price and availability on request

Request a quote

Sent with the product details: Lutron VB-8100 Vibration Meter, Acceleration / Velocity / Displacement, RS232.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Applications for industrial vibration monitoring: All industrial machinery vibrates. The level of vibration is a useful guide to machine condition. Poor balance,misalignment & looseness of the structure will cause the vibration level increase, it is a sure sign that the maintenance is needed.
  • Frequency range 10 Hz - 1 kHz, sensitivity relative meet ISO 2954.
  • Professional vibration meter supply with vibration sensor & magnetic base, full set.
  • Metric & Imperial display unit
  • Acceleration, Velocity, Displacement measurement.
  • RMS, Max hold, Peak value measurement.
  • Max. Hold reset button, Zero button.
  • Wide frequency range.
  • Data hold button to freeze the desired reading.
  • Memory function to record maximum and minimum reading with recall.
  • Separate vibration probe with magnetic base, easy operation.
  • LCD with green light backlight, easy reading.
  • Can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Microcomputer circuit, high accuracy.
  • Power by UM3/AA (1.5 V) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.

Specifications

Specifications
CircuitCustom one-chip of microprocessor LSI circuit.; Exclusive microcomputer circuit.
DisplayLCD size : 52 mm x 38 mm; LCD with green backlight ( ON/OFF ).
MeasurementVelocity, Acceleration, Displacement
FunctionAcceleration, Velocity : RMS, Peak, Max Hold.; Displacement : p-p ( peak-peak ), Max Hold p-p.
UnitMeasurement Metric Imperial; Acceleration m/s^2, g ft/s^2; Velocity mm/s, cm/s inch/s; Displacement mm inch
Frequency range10 Hz to 1 KHz.; * Sensitivity relative during the the frequency range meet ISO 2954 Refer to table 1, page 21.
Peak MeasurementAcceleration, Velocity : To measure and update the peak value.; Displacement : To measure and update the peak to peak; ( p-p ) value.
Max Hold MeasurementAcceleration, Velocity : To measure and update the max. peak value.; Displacement : To measure and update the max. peak to peak ( p-p ) value.
Zero ButtonUnder Acceleration ( RMS ) measurement, sensor motionless, press two Buttons ( 3-5, 3-6, Fig. 1 ) >3 seconds.
Max. Hold Reset ButtonUnder Max. hold measurement, press two Buttons ( 3-5, 3-6, Fig. 1 ) >3 seconds.
Advanced setting* Set clock time ( Year/Month/Date, Hour/Minute/ Second ); * Auto power OFF management; * Set beep Sound ON/OFF; * Set sampling time
Data HoldFreeze the display reading.; * Only available for the RMS function.
Memory RecallMaximum & Minimum value.; * Only available for the RMS function.
Data OutputRS 232/USB PC computer interface.; * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.; * Connect the optional USB cable USB-01 will get the USB plug.
Sampling Time of DisplayApprox. 1 second.
Operating Temperature and Humidity0 to 50 °C.; Less than 85% R.H.
Power Supply* Alkaline or heavy duty DC 1.5 V battery; ( UM3, AA ) x 6 PCs, or equivalent.; * DC 9V adapter input. ( AC/DC power adapter is optional ).
Power CurrentNormal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 15 mA.; When SD card save the data and LCD Backlight is OFF) : Approx. DC 36 mA.
WeightMeter : 360 g/ 0.79 LB.; Probe with cable and magnetic base : 99 g/0,22 LB.
DimensionMeter : 182 x 73 x 47.5 mm Vibration sensor probe: Round 16 mm Dia. x 37 mm. Cable length : 1.2 meter.
Accessories
Supplied withInstruction manual: 1 PC; Hard carrying case(CA-06): 1 PC; Vibration sensor with cable: 1 PC; Magnetic base: 1 PC
Optional*AC to DC 9V adapter.
Measurement Functions
Range0.5 to 199.9 m/s², 0.05 to 20.39 g, 2 to 656 ft/s²
Resolution0.1 m/s², 0.01 g, 1 ft/s²
Accuracy±⁠(5% + 5d) @ 160 Hz, 80 Hz, 23 ± 5°C
Calibration Point50 m/s² (160 Hz)
Range0.5 to 199.9 mm/s, 0.05 to 19.99 cm/s, 0.02 to 7.87 inch/s
Resolution0.1 mm/s, 0.01 cm/s, 0.01 inch/s
Calibration Point50 mm/s (160 Hz)
Range1.999 mm, 0.078 inch
Resolution0.001 mm, 0.001 inch
Calibration Point0.141 mm (160 Hz)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.