Lutron TU-2016 Turbidity Meter, 0 to 1,000 NTU, ISO 7027

Brand
Lutron
Model number
TU-2016

Turbidity meter to ISO 7027 with auto range from 0 to 1,000 NTU, 0.01 NTU resolution, 850 nm LED source and two-point calibration.

Price and availability on request

Request a quote

Sent with the product details: Lutron TU-2016 Turbidity Meter, 0 to 1,000 NTU, ISO 7027.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Designed to meet ISO 7027.
  • NTU (Nephelometric TURBIDITY Unit) measuring unit.
  • Wide and auto measurement range: 0 to 1,000 NTU.
  • High resolution: 0.01 NTU/1 NTU.
  • The unique optics structure, enables the instrument to read low value of TURBIDITY to the high level up to 1,000 NTU.
  • Four operation buttons and two calibration points, easy operation.
  • Jumbo LCD, easy readout.
  • Microprocessor circuit assures maximum possible accuracy, provides special functions and features.
  • Battery operated for field and on-site testing convenience.
  • Data hold function for freezing the desired value on display.
  • Records Maximum and Minimum readings with Recall.
  • Heavy duty & compact housing with hard carrying case, designed for easy carry out & operation.
  • Auto shut off is available to save battery life.
  • Application: Test municipal water, food and beverage water, or other aqueous solution where fluid clarity is important.

Specifications

Specifications
CircuitCustom one-chip of microprocessor LSI circuit.
DisplayLCD size : 41 mm x 34 mm
Range0.00 to 50.00 NTU, 50 to 1,000 NTU; * NTU : Nephelometric Turbidity Unit; * Auto range
Resolution0.00 to 49.99 NTU,0.01 NTU; 50 to 1000 NTU, 1 NTU
Accuracy0.00 to 49.99 NTU : ± 5% reading or ± 0.5 NTU, whichever is greater.; 50 to 1000 NTU : ± 5% reading or ± 5 NTU, whichever is greater.
Light sourceLED, 850 nm.
DetectorPhoto diode
StandardMeet ISO 7027.
Response timeLess than 10 seconds.
Sample volume needed10 mL.
Data HoldFreeze the display reading.
Memory RecallMaximum & Minimum value.
Display Sampling TimeApprox. 1 second.
Power offAuto shut off saves battery life or manual off by; push button.
Calibration points0 NTU, 100 NTU.
Operating Temperature0 to 50 °C.
Operating HumidityLess than 85% R.H.
Power SupplyDC 1.5 V battery (UM4, AAA) x 6 PCs or DC 9V adapter.
Power CurrentStand by : Approx. DC 3.5 mA.; Testing : Approx. DC 36 mA.
Weight320 g/0.70 LB.; @ Battery is included.
Dimension155 x 76 x 62 mm ( 6.1 x 3.0 x 2.4 inch)
Accessories
Supplied withTesting bottle with 0 NTU standard solution : 1 PC; Testing bottle with 100 NTU standard solution : 1 PC; Empty testing bottle : 2 PCs; Clean cloth : 1 PC; Clean solution ( Distill water ) : 1 bottle; Hard carrying case, CA-07A : 1 PC
Optional* Testing bottle with 100 NTU standard solution, TU-100NTU.; * Testing bottle with 0 NTU standard solution, TU-0NTU.; * Empty testing bottle, 0601.; * AC to DC 9V power adapter.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.