Lutron TM-926 Thermocouple Thermometer, Type K/J/T/E/R, Compact
- Brand
- Lutron
- Model number
- TM-926
- Category
- Thermometers & Hygrometers
Thermocouple thermometer for type K, J, T, E and R probes with 0.1 degree resolution, max/min, relative and data hold.
Price and availability on request
Key features
- Type J/K/R/E/T thermocouple thermometer.
- Temp. probe accept 5 different types: type K, type J, type R, type T, type E.
- Microcomputer circuit with excellent performance.
- Wide temperature measuring range.
- °C& °F select button.
- 0.1 degree resolution for type K/J/T/E.
- Data hold.
- Memory function to record the maximum & minimum reading.
- REL button for relative measurement.
- Sensor select button on the front panel, easy to change different type probe.
- RS 232 data output.
- Optional data acquisition software for data record.
- Auto power off saves battery life.
- Heavy duty & compact housing case with stand.
- Powered by 006P DC 9V battery.
Specifications
| Circuit | Exclusive microcomputer circuit, the software build in linearity correction function instead of the traditional hardware circuit. |
|---|---|
| Display | 51 mm x 32 mm supper large LCD display; 15 mm ( 0.6" ) digit size. |
| Power Consumption | Approx. DC 11 mA. |
| Data Output | RS232 PC serial interface. |
| Operating temperature | 0 to 50°C (32 to 122°F ). |
| Operating Humidity | Less than 80% RH. |
| Power Supply | Alkaline or heavy duty type; DC 9V battery, 006P, MN1604 ( PP3 ); or equivalent |
| Weight | 220 g/0.48 LB |
| Data Hold | To freeze the display reading value. |
| Memory Recall | Memorize the Maximum, Minimum reading. |
| Over Indication | Show " - - - - ". |
| Functions | °C, °F, Data hold, Memory ( Max., Min. ); Relative measurement |
| Resolution | Data hol °C °F d, Memory ( Max., Min. ), 0.1 °F -58.0 to 752.0 °F ± ( 0.2 % + 1 ) °F; Relative measurement |
| Optional | Thermocouple couple ( Type K ) probe : Model : TP-01, TP-02A, TP-03, TP-04.; RS232 cable, Model : UPCB-02.; USB cable, Model : USB-01.; Application software, windows version. Model : SW-E816. |
|---|
| Range | -50.0 to 1300.0°C (Resolution: 0.1°C, Accuracy: ±(0.2% + 0.5°C)) |
|---|---|
| Range | -58.0 to 2372.0°F (Resolution: 0.1°F, Accuracy: ±(0.2% + 1°F)) |
| Range | -50.0 to 1150.0°C (Resolution: 0.1°C, Accuracy: ±(0.2% + 0.5°C)) |
| Range | -58.0 to 2102.0°F (Resolution: 0.1°F, Accuracy: ±(0.2% + 1°F)) |
| Range | -50.0 to 400.0°C (Resolution: 0.1°C, Accuracy: ±(0.2% + 0.5°C)) |
| Range | -50.0 to 900.0°C (Resolution: 0.1°C, Accuracy: ±(0.2% + 0.8°C)) |
| Range | -58.0 to 1652.0°F (Resolution: 0.1°F, Accuracy: ±(0.2% + 1.5°F)) |
| Range | 0 to 1700°C (Resolution: 1°C, Accuracy: ±(1% + 5°C) for 0 to 600°C, ±(1.5% + 5°C) for 601 to 1700°C) |
| Range | 32 to 3092°F (Resolution: 1°F, Accuracy: ±(1% + 10°F) for 32 to 1112°F, ±(1.5% + 10°F) for 1113 to 3092°F) |
| Main Instrument | 195 x 68 x 30 mm (7.6 x 2.6 x 1.2 inches) |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.