Lutron ESF-106 Electrostatic Field Meter, ±19.999 kV
- Brand
- Lutron
- Model number
- ESF-106
- Category
- EMF & Radiation Meters
Non-contact static voltage meter reading -19.999 to +19.999 kV with 0.001 kV resolution and an adjustable high voltage alarm.
Price and availability on request
Key features
- Professional precision STATIC Voltage meter with 0.001 kV resolution, digital display, battery operated.
- LSI - circuit provides high reliability and durability.
- Operation directly.
- Measurement range: -19.999 kV to +19.999 kV.
- High voltage alarm: +/- 18.000 kV.
- ALARM setting: 0.010 kV to 18.000 kV.
- Data hold, Record (Max., Min.).
- LCD with green light backlight, easy reading.
- RS232 / USB Computer interface.
- Built-in low battery indicator.
- Power: DC 9V (006P).
Specifications
| Display | LCD size : 51 mm x 30 mm, Max. indication : ± 19999.; LCD with backlight ( On/Off ). |
|---|---|
| Circuit | Custom one-chip of microprocessor LSI circuit. |
| Measurement | Static Voltage : -19.999 kV to +19.999 kV |
| Over input | " ---- " mark indication. |
| Zero adjustment | ZERO button. |
| Sampling time | Approx. 0.5 second. |
| Data hold | Freeze the display reading. |
| Memory recall | Maximum and Minimum value. |
| Data output | RS232/USB PC Computer interface.; * Connect the optional RS232 cable, UPCB - 02 will get; the RS232 plug.; * Connect the optional USB cable, USB - 01 will get the; USB plug. |
| Operation Temp. | 0 to 50 ( 32 to 122 ). |
| Operation humidity | Less than 80% RH. |
| Power supply | Alkaline or Heavy duty type DC 9V battery.; 006P, MN1604 (PP3) or equivalent |
| Power consumption | Approx. DC 6 mA |
| Weight | 215 g / 0.476 LB |
| Dimension | 195 x 68 x 30 mm ( 7.6 x 2.6 x 1.2 inch ). |
| Supplied with | Instruction manual: 1 PC; 1" Magnetic Spacer: 1 PC; Ground wire: 1 PC; Ground CLIP: 1 PC; Carrying case, CA-06: 1 PC |
|---|---|
| Optional | * USB cable, USB-01.; * RS232 cable, UPCB-02.; * Data Acquisition software, SW-E816.; * Excel Data Acquisition software, SW-E802. |
| Resolution | 0.001 kV |
|---|---|
| Accuracy | ±(5% + 50d) @ 23 ± 5°C |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.