Lutron DL-6054 AC Leakage Current Clamp Tester

Brand
Lutron
Model number
DL-6054

Miniature clamp tester for AC leakage current with 200 mA, 20 A and 200 A ranges, 0.1 mA resolution and a 19 mm jaw, with data hold.

Price and availability on request

Request a quote

Sent with the product details: Lutron DL-6054 AC Leakage Current Clamp Tester.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • High precision AC mA measurement, it is useful for AC mA leakage current measurement.
  • Measure AC mA on the inductive conductor.
  • Miniature type, easy to carry out & operation.
  • High precision for low ACA leakage current measurement.
  • Built-in DATA HOLD function.
  • Crystal time base, high quality.
  • LCD display allows clear readout-out even at high ambient light level.
  • LSI circuit provides high reliability and durability.
  • Overload protection circuit is provided for all range.
  • Design to meet IEC 1010 safety requirement.
  • Compact, light weight and excellent operation.

Specifications

Specifications
CircuitLSI circuit provides high reliability and durability
Display13 mm ( 0.5" ) LCD, 3 1/2 digits.; Max. indication 1999.
Measurements200 AC mA x 0.1 mA; 20 ACA x 0.01 A; 200 ACA x 0.1 A
A/D counts no.1999 counts.
Current ranges200 AC mA; 20 ACA; 200 ACA
Safety standardt IEC 1010 safety requirement.
Clamp frequency responsesine wave 50,to 400 Hz
Over-load protection300 ACA max. ( within 1 minute for 20A, 200A range ).
Over-rangeDisplay shows '1'.
Data HoldAvailable to hold the measuring values on the display.
Range selectionManual select
Display sampling timeApprox. 0.4 second.
Operating Temperature0 to 50°C ( 32 to 122°F ).
Operating HumidityLess than 80% RH.
Power Supply006P DC 9V battery.
Power ConsumptionApprox. DC 1.2 mA.
Max. Conductor size19 mm Dia
DimensionsHWD 180 x 47 x 35 mm.; 7.1 x 1.9 x 1.4 inch.
Current SensorHall effect sensor.
Zero adjustmentAutomatic adjustment.
Weight200 g/0.44 LB ( including battery ).
Accessories
Supplied withOperation manual:1 PC.; Carrying case:1 PC.
Technical details
Accuracy± (1.2% + 5d) at 23°C ± 5°C * Specification be tested on sine wave 50, 60 Hz.
Time BaseQuartz crystal, 32768 Hz

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.