Lutron CM-6155C AC/DC Clamp Meter, 1000 A, with Temperature

Brand
Lutron
Model number
CM-6155C

Smart AC/DC clamp meter for 600 A and 1000 A ranges with 6000 counts, voltage, resistance, capacitance, frequency and temperature; CAT III 1000 V.

Price and availability on request

Request a quote

Sent with the product details: Lutron CM-6155C AC/DC Clamp Meter, 1000 A, with Temperature.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Meet IEC 1010 CAT III 1000 V safety requirement.
  • 6000 counts A/D, high resolution.
  • ACV, ACA, DCV, DCA, ohms, continuity, Hz, Capacitance, Diode, Temperature.
  • Smart function, Auto range or manual range with hold.
  • Smart operation, Build in 4 intelligent function: " V ", " Ω "," 600A ", " 1000A ".
  • V " function can select ACV, DCV automatically with auto range.
  • " Ω " function can select the Resistance, Diode, Continuity beeper, Capacitance automatically with auto range.
  • " 600A " & " 1000A " function can select ACA, DCA automatically.
  • Data hold.
  • Auto shut off is available to save battery life.
  • 10 M ohm impedance for voltage circuit.
  • Built-in overload protection for most ranges.
  • LSI circuit provides high reliability and durability.
  • Uses durable, long-lasting components, enclosed in strong, light weight ABS-plastic housing.
  • Full line optional adapters: Clamp adapter, Tachometer adapter, Pressure adapter, Humidity Adapter, Sound level adapter, Anemometer adapter, Light adapter, EMF adapter.

Specifications

Specifications
CircuitLSI circuit provides high reliability and durability
Display39.5 mm x29.8 mm large LCD display
MeasurementsDCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Diode, Continuity beeper, Temperature.
A/D counts no.6000 counts.
Voltage rangesAC Voltage : 6 V/60 V/600 V /1000 V; DC Voltage : 600 mV /6 V/60 V/600 V /1000 V
Current rangesDC Current, AC Current : 600A/1000A
Safety standardIEC 1010 CATIII 1000V safety
ACV input impedance10 M ohm impedance for voltage circuit.
Clamp frequency responseACA specification be tested on sine wave 50/60 Hz.
Over-load protectionOverload protection circuit is provided for all ranges
Over-rangeIndication of " OL " or " -OL ".
Data HoldTo freeze the display reading on the LCD display
DCA zero adj.DCA : Push bottom adjustment.
Range selectionUnder auto function. push range button to range selecting.
Display sampling timeApprox. 0.5 to 1 second.
Operating Temperature0 °C to 50 °C (32°F to 122°F )
Operating HumidityMax. 80% RH.
Power SupplyDC 9 V battery 006P,MN1604
Power ConsumptionApprox. DC 9.1 mA.
Max. Conductor size32 mm (1.3 inch) Dia..
Dimensions241 x94 x 46 mm ( 9.5 x 3.7 x 1.8 inch ).
PolarityAutomatic Switching, " - " indicates negative polarity.
Current SensorHall effect sensor.
Zero adjustmentDCA : Push bottom adjustment.; Other ranges : Automatic adjustment.
Weight384 g/0.95 LB ( w/o battery ).
Max. Jaw Open SizeSame Conductor size
Accessories
Supplied with* Red and Black Test Leads : 1 Set; * Instruction Manual : 1 PC; * Soft carrying case : 1 PC
OptionalFull line adapters : ACA/DCA current adapter; Tachometer adapter; Humidity adapter, Pressure adapter; Light adapter, EMF adapter; Sound level adapter; High voltage probe.
Measurement Ranges
Resolution0.1 mV to 1 V
Accuracy± (0.8% + 2d) to ± (0.8% + 1d)
Resolution0.001 V to 1 V
Accuracy± (1% + 2d)
Resolution0.1 A to 1 A
Accuracy± (1.5% + 15d) to ± (2% + 8d)
Resolution0.1 ohm to 1 M ohm
Accuracy± (1% + 2d) to ± (1.5% + 2d)
Resolution0.001 nF to 0.1 uF
Accuracy± (3% + 5d)
Range40 Hz to 1 kHz
Resolution0.001 kHz
Accuracy± (0.5% + 2d)
Temperature (Type K)
Range-20 to 750°C
Resolution0.1°C

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.