Lutron AM-4307SD Vane Anemometer with Air Flow and Thermocouple Input, SD Logger

Brand
Lutron
Model number
AM-4307SD
Category
Anemometers

Vane anemometer for air velocity, air flow (CFM/CMM) and air temperature that also takes a type K/J thermocouple probe, with real-time SD card logging.

Price and availability on request

Request a quote

Sent with the product details: Lutron AM-4307SD Vane Anemometer with Air Flow and Thermocouple Input, SD Logger.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • One meter can accept two probes: Anemometer probe, Thermocouple probe.
  • Air velocity: m/s, Ft/min, Km/h, Knot, Mile/h.
  • Air flow (CFM, CMM) measurement.
  • Air temperature (°C, °F).
  • Air Temp. used thermistor sensor, fast response time.
  • Type K, Type J thermocouple thermometer.
  • Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder, sampling time set from 1 second to 3600 seconds.
  • Manual datalogger is available (set the sampling time to 0), during execute the manual datalogger function, it can set the different position (location) No. (position 1 to position 99).
  • Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer, it can down load the all the measured value with the time information (year/month/date/ hour/minute/second) to the Excel directly, then user can make the further data or graphic analysis by themselves.
  • SD card capacity: 1 GB to 16 GB.
  • LCD with green light backlight, easy reading.
  • Can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Microcomputer circuit, high accuracy.
  • Power by UM3/AA (1.5 V) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.
  • Separate probe, easy for operation.
  • Applications: Environmental testing, HVAC, Air conveyors, Flow hoods, Clean rooms, Air velocity, Air balancing, Fans/motors/blowers, Furnace velocity, Refrigerated case, Paint spray booths. measurements

Specifications

Specifications
DisplayLCD size : 52 mm x 38 mm; LCD with green backlight ( ON/OFF ).
Anemometer UnitAir velocity: m/s (meters per second); Km/h ( kilometers per hour ); Ft/min ( FPM, feet per minute ); Knots ( nautical miles per hour ); Mile/h ( mph, miles per hour ); Air flow : CFM, CMM; * CFM : cube feet per minute; * CMM : cube meters per minute; °C, °F; Type K/ Type J thermometer : °C, °F.; Air temperature:°C, °F.
CircuitCustom one-chip of microprocessor LSI circuit.
Data HoldFreeze the display reading.
Memory RecallMaximum & Minimum value.
Operating Temperature0 to 50°C.
Operating HumidityLess than 85% R.H.
Power Supply* Alkaline or heavy duty DC 1.5 V battery( UM3, AA ) x 6 PCs, or equivalent.; * DC 9V adapter input. ( AC/DC power adapter is optional ).
Power CurrentNormal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 30 mA.; When SD card save the data and LCD Backlight is OFF) : Approx. DC 50 mA.
Weight347 g/ 0.76 LB. * Meter only
DimensionMain instrument : 182 x 73 x 47.5 mm; ( 7.1 x 2.9 x 1.9 inch ); Anemometer sensor probe : 72 mm Dia.
Memory CardSD memory card. 1 GB to 16 GB.; * It recommend use memory card 4 GB.
Advanced setting* Set clock time ( Year/Month/Date, Hour/Minute/ Second ); * Set sampling time; * Auto power OFF management; * Set beep Sound ON/OFF; * Decimal point of SD card setting; * SD memory card Format; * Set thermometer type to Type K or Type J; * Set temperature unit to or °C °F; * Set air flow type ( CFM/USA, CMM/EURO ); * Set air flow area dimension
Temperature CompensationAutomatic temp. compensation for the Anemometer function and the type K/J thermometer.
Data OutputRS 232/USB PC computer interface.; * Connect the optional RS232 cable; UPCB-02 will get the RS232 plug.; * Connect the optional USB cable; USB-01 will get the USB plug.
Accessories
Supplied withInstruction manual:1 PC; Anemometer probe:1 PC; Hard carrying case (CA-06):1 PC
Optional* SD Card ( 4 G ); * Type K thermocouple probes, refer to page 27.; * AC to DC 9V adapter.; * USB cable, USB-01.; * RS232 cable, UPCB-02.; * Data Acquisition software, SW-E816.; * Excel Data Acquisition software, SW-E802
Measurement Range and Resolution
m/s0.2 to 5.0 m/s (Resolution: 0.01 m/s, Accuracy: ±⁠(5% + 0.1 m/s)), 5.1 to 25.0 m/s (Resolution: 0.1 m/s, Accuracy: ±⁠(1% + 0.1 m/s))
mile/h0.5 to 11.2 mph (Resolution: 0.01 mph, Accuracy: ±⁠(5% + 0.2 mph)), 11.2 to 44.7 mph (Resolution: 0.1 mph, Accuracy: ±⁠(1% + 0.2 mph))
knots0.4 to 9.7 knots (Resolution: 0.01 knots, Accuracy: ±⁠(5% + 0.2 knots)), 9.7 to 38.8 knots (Resolution: 0.1 knots, Accuracy: ±⁠(1% + 0.2 knots))
ft/min40 to 3940 ft/min (Resolution: 1 ft/min, Accuracy: ±⁠(5% + 20 ft/min))
CMM0 to 54,000 CMM (Resolution: 0.001 to 1 CMM, Accuracy: ±⁠(1% + 0.1 CMM))
CFM0 to 1,907,000 CFM (Resolution: 0.001 to 100 CFM, Accuracy: ±⁠(1% + 0.1 CFM))
Range0 to 50°C (32 to 122°F), Resolution: 0.1°C/°F, Accuracy: ±0.8°C/1.5°F
Range-50 to 1300°C (-58 to 2372°F), Resolution: 0.1°C/°F, Accuracy: ±⁠(0.4% + 0.5°C)/±⁠(0.4% + 1°F)
Range-50 to 1200°C (-58 to 2192°F), Resolution: 0.1°C/°F, Accuracy: ±⁠(0.4% + 0.5°C)/±⁠(0.4% + 1°F)
Data Logging
Sampling TimeAuto from 1 second to 3600 seconds, Manual data logging available
Operating Environment
Temperature0 to 50°C (32 to 122°F)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.