Key features

  • Two probes are included: Anemometer probe and Humidity/Temp. probe.
  • 3 in 1: Anemometer, Humidity/Temp. meter, Type J/K thermometer.
  • ABS plastic vane probe, heavy duty.
  • Air velocity: m/S, Ft/min, Km/h, Knots, Mile/h,
  • Air temperature (°C, °F)
  • Air flow: CMM, CFM.
  • Low-friction ball vane wheels make sure high accuracy in high & low velocities.
  • Type K, Type J thermocouple thermometer.
  • Air Temp. used thermistor sensor, fast response time.
  • Humidity/%RH: 10 to 95 %RH.
  • Dew point. Wet bulb Temp..
  • Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder, sampling time set from 1 second to 3600 seconds.
  • Manual datalogger is available (set the sampling time to 0), during execute the manual datalogger function, it can set the different position (location) No. (position 1 to position 99).
  • Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer, it can down load the all the measured value with the time information (year/month/date/ hour/minute/second) to the Excel directly, then user can make the further data or graphic analysis by themselves.
  • SD card capacity: 1 GB to 16 GB.
  • LCD with green light backlight, easy reading.
  • Can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Microcomputer circuit, high accuracy.
  • Power by UM3/AA (1.5 V) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.
  • Separate probe, easy for operation of different measurement environment.
  • Wide applications: use this anemometer to check air conditioning & heating systems, measure air velocities, wind temperature...etc.

Specifications

Specifications
DisplayLCD size : 52 mm x 38 mm; LCD with green backlight ( ON/OFF ).
CircuitCustom microprocessor LSI circuit.
Data HoldFreeze the display reading.
Memory RecallMaximum & Minimum value.
Sampling TimeApprox. 1 second.
Operating Temperature0 to 50 °C.; * meter only
Operating HumidityLess than 85% R.H.
Power Supply* Battery : Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.; * ACV : ADC 9V adapter input. ( AC/DC power adapter is optional ).
Power CurrentNormal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 15 mA.; When SD card save the data and LCD Backlight is OFF) : Approx. DC 36 mA.
Weight347 g/ 0.76 LB.; * Meter only
DimensionMain instrument : 182 x 73 x 47.5 mm ( 7.1 x 2.9 x 1.9 inch ); Anemometer sensor head : Round, 72 mm Dia.; Humidity Probe : 197 mm ( 7.8 inch ) in length.
MeasurementAir velocity : m/S (meters per second); Km/h ( kilometers per hour ); Ft/min ( FPM, feet per minute ); Knots ( nautical miles per hour ); Mile/h ( mph, miles per hour ); Air temperature :, °C °F; Air flow : CMM, CFM.; Humidity/Temp. : %RH/ or. °C °F; Dew point ( Humidity ) : or. °C °F; Wet bulb ( Humidity ) : or. °C °F; Type K/ Type J thermometer :, °C °F
Datalogger Sampling Time Setting rangeAuto : 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800 3600 second.; @ Sampling time can set to 1 second, but memory data may loss.; Manual : Push the data logger button once will save data one time. @ Set the sampling time to 0 second.; @ Manual mode, can also select the 1 to 99 position ( Location ) no.
Memory CardSD memory card. 1 GB to 16 GB.
Advanced setting* Set clock time ( Year/Month/Date, Hour/Minute/ Second ); * Decimal point of SD card setting; * Auto power OFF management; * Set beep Sound ON/OFF; * Set thermometer type to Type K or Type J; * Set temperature unit to or °C °F; * Set sampling time; * SD memory card Format
Temperature CompensationAutomatic temp. compensation for the type K/J thermometer.
Data OutputRS 232/USB PC computer interface.; * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.; * Connect the optional USB cable USB-01 will get the USB plug.
Accessories
Supplied with* Instruction manual : 1 PC; * Anemometer probe : 1 PC; * Humidity probe : 1 PC; * Hard carrying case ( CA-06 ) : 1 PC
Optional* SD Card ( 4 G ); * Type K thermocouple probe.; * AC to DC 9V adapter.; * USB cable, USB-01.; * RS232 cable, UPCB-02.; * Data Acquisition software, SW-E816.; * Excel Data Acquisition software, SW-E802.
Measurement Functions
Range0 to 80°C (32 to 176°F)
Resolution0.1°C/°F
Accuracy±0.8°C (±1.5°F)
Range10 to 95 %RH
Resolution0.1 %RH
°C-25.3 to 48.9°C
°F-13.5 to 120.1°F
°C-21.6 to 50.0°C
°F-6.9 to 122.0°F
Type K±⁠(0.4% + 0.5°C) / ±⁠(0.4% + 1°F)
Type J±⁠(0.4% + 0.5°C) / ±⁠(0.4% + 1°F)
Operating Environment
Temperature0 to 50°C (32 to 122°F)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.