Kusam Meco KM 2100 Multifunction Power and Harmonics Analyser, Class S, with Flicker, Transients and Inrush

Model number
KM 2100

Portable Class S power quality analyser to IEC 61000-4-30 and EN 50160: 1000 V, 5000 A with clamps, harmonics and interharmonics, flicker, transients, inrush, dips and swells, unbalance, energy; 8 GB logging, LAN.

Price and availability on request

Request a quote

Sent with the product details: Kusam Meco KM 2100 Multifunction Power and Harmonics Analyser, Class S, with Flicker, Transients and Inrush.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Downloads

Key features

  • Run chart, bar chart, vector, waveform, event list, readings, trend, dips and swells
  • Flicker, transients and inrush current
  • Voltage and current unbalance; active, reactive and apparent energy
  • Long-term logging to the built-in memory card
  • USB and LAN; PC analysis software

Specifications

Measurement
VoltageVrms (AC+DC) 1 – 1000 Vrms, 0.1 V, ±0.5% of nominal voltage; Vpk 1 – 1400 Vpk; crest factor 1.0 – > 2.8
Current (Arms AC)0 – 100 A (10 mV/A clamp), 1 – 1000 A (1 mV/A): ±0.5% ± 0.2 A; 15 – 5000 A: ±1% ± 2 A
Power factor0 – 1, resolution 0.01, ±0.03 (also displacement power factor)
HarmonicsOrders 1 – 50; harmonic voltage and current 0.0 – 100.0%, ±0.1% ± n×0.1%; THD 0.0 – 100.0%, ±2.5%; DC relative ±0.2%
Dips and swellsVrms ½ cycle 0 – 200% of nominal, ±1%; dips, swells, interruptions and rapid voltage change; duration resolution 0.5 cycle
LoggerUser-defined parameters for 4 phases; interval 1 s – 1 h; duration 2 h – 1 year; TF card 8 GB
Sampling8 channels, 16-bit AD, 20 kS/s per channel, synchronous; 5000 points per 10/12 cycles (IEC 61000-4-30); PLL 4096 points (IEC 61000-4-7)
Current inputs4 (3 phase + neutral), DC coupled, clamp sensors with mV output, 1 – 5000 Arms with clamps, 50 kΩ, bandwidth > 3 kHz
Frequency42.5 – 57.5 Hz (50 Hz), 51 – 69 Hz (60 Hz): ±0.01 Hz; 385 – 414 Hz (400 Hz): ±0.1 Hz
Power and energyActive, apparent and reactive power 1.0 – 20.00 MW, resolution 0.1 kW; energy 0.00 kWh – 200 GWh
Interharmonics1 – 49
FlickerPst (1 min), Pst, Plt, PF5: 0.00 – 20.00, within ±5% of IEC 61000-4-15 table value
Voltage transients6000 Vpk (±15%); 10 – 1000 Vrms (±2.5%); minimum test time 50 µs; 20 kS/s
Inrush current0 – 3000 Arms (AC + DC), ±⁠(1% ± 5 counts); duration 6 s – 32 min, ±20 ms
UnbalanceVoltage 0.0 – 5.0% (±0.5%); current 0.0 – 20.0% (±1%)
Distortion factorTHD 0.0 – 100.0%, ±2.5%
General
Display5.6" TFT LCD, 320 × 240, adjustable brightness; waveform, phasor and table display
Wiring1-phase 2W, 1-phase 3W, 3-phase 3W, 3-phase 4W
Memory128 MB flash; built-in 8G TF card
InterfacesUSB (download by U-disk); LAN for remote control and data transfer
Power supplyAdaptor 90 – 264 V input, 12 V 2 A output; rechargeable Ni-MH 7.2 V 3.8 Ah, > 7 hours, 6 hours charge
Working temperature0 °C – 40 °C
Storage temperature−20 °C – 60 °C
ProtectionIP51 (IEC 60529)
Dimensions262 × 173 × 66 mm
WeightApprox. 1.6 kg
Accessories5 voltage test leads (2 m), 5 alligator clips, external DC adaptor, hang strap, software CD, user manual and carrying case
Optional accessoriesCurrent clamps 5 A to 5000 A: ST08 (5 A), CTC0080 (50 A), CTC0130 (100 A), CTC1535 (1000 A), 035AD (AC/DC 1000 A), SY-1500A, PY-3000A, PY-5000A
Safety
CategoryCAT III 1000 V / CAT IV 600 V; pollution degree 2
StandardsIEC 61000-4-30 (2008) Class S, EN 50160 (2007); safety IEC 61010-1

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.