HTC Instruments 8250 5 kV Digital Insulation Resistance Meter

Model number
8250

5 kV digital insulation resistance meter with six test voltages (100 V, 250 V, 500 V, 1000 V, 2500 V, 5000 V), up to 10 TΩ, PI and DAR, ramp and filter tests, DC current, capacitance, 500-group memory and USB. Rechargeable.

Price and availability on request

Request a quote

Sent with the product details: HTC Instruments 8250 5 kV Digital Insulation Resistance Meter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Six test voltages: 100 V, 250 V, 500 V, 1000 V, 2500 V, 5000 V
  • Insulation resistance up to 10 TΩ
  • Polarization index (PI) and dielectric absorption ratio (DAR)
  • Ramp (oblique wave) test and filter test
  • DC voltage to 1000 V, AC voltage to 750 V
  • DC current from 100 pA to 6 mA
  • Capacitance 10 nF to 50 µF
  • Large 4-digit LCD (108 × 65 mm) with switchable backlight
  • Data storage, 500 groups, with review
  • USB interface; PC software to monitor, store and print
  • Settable alarm value
  • High voltage indication
  • Auto power off after 15 minutes
  • Shock-proof, dust-proof and moisture-proof case
  • Rechargeable battery

Specifications

Insulation resistance at 100 V (±10%)
Ranges (resolution)0.05 MΩ – 0.5 MΩ (0.001 MΩ), 0.5 MΩ – 5 MΩ (0.01 MΩ), 5 MΩ – 50 MΩ (0.1 MΩ), 50 MΩ – 500 MΩ (1 MΩ), 0.5 GΩ – 5 GΩ (0.01 GΩ), 5 GΩ – 50 GΩ (0.1 GΩ), 50 GΩ – 500 GΩ (1 GΩ)
Accuracy0.05 MΩ – 5 GΩ: ±⁠(3% of reading + 5); 5 GΩ – 50 GΩ: ±⁠(10% of reading + 5); 50 GΩ – 500 GΩ: ±⁠(20% of reading + 5)
Insulation resistance at 250 V (±10%)
Ranges (resolution)0.1 MΩ – 1 MΩ (0.001 MΩ), 1 MΩ – 10 MΩ (0.01 MΩ), 10 MΩ – 100 MΩ (0.1 MΩ), 100 MΩ – 1000 MΩ (1 MΩ), 1 GΩ – 10 GΩ (0.01 GΩ), 10 GΩ – 100 GΩ (0.1 GΩ), 100 GΩ – 1000 GΩ (1 GΩ)
Accuracy0.1 MΩ – 10 GΩ: ±⁠(3% of reading + 5); 10 GΩ – 100 GΩ: ±⁠(10% of reading + 5); 100 GΩ – 1000 GΩ: ±⁠(20% of reading + 5)
Insulation resistance at 500 V (±10%)
Ranges (resolution)0.2 MΩ – 2 MΩ (0.001 MΩ), 2 MΩ – 20 MΩ (0.01 MΩ), 20 MΩ – 200 MΩ (0.1 MΩ), 200 MΩ – 2000 MΩ (1 MΩ), 2 GΩ – 20 GΩ (0.01 GΩ), 20 GΩ – 200 GΩ (0.1 GΩ), 200 GΩ – 2000 GΩ (1 GΩ)
Accuracy0.2 MΩ – 20 GΩ: ±⁠(3% of reading + 5); 20 GΩ – 200 GΩ: ±⁠(10% of reading + 5); 200 GΩ – 2000 GΩ: ±⁠(20% of reading + 5)
Insulation resistance at 1000 V (±10%)
Ranges (resolution)0.5 MΩ – 5 MΩ (0.001 MΩ), 5 MΩ – 50 MΩ (0.01 MΩ), 50 MΩ – 500 MΩ (0.1 MΩ), 500 MΩ – 5000 MΩ (1 MΩ), 5 GΩ – 50 GΩ (0.01 GΩ), 50 GΩ – 500 GΩ (0.1 GΩ), 500 GΩ – 5000 GΩ (1 GΩ)
Accuracy0.5 MΩ – 50 GΩ: ±⁠(3% of reading + 5); 50 GΩ – 500 GΩ: ±⁠(10% of reading + 5); 500 GΩ – 5000 GΩ: ±⁠(20% of reading + 5)
Insulation resistance at 2500 V (±10%)
Ranges (resolution)1 MΩ – 10 MΩ (0.01 MΩ), 10 MΩ – 100 MΩ (0.1 MΩ), 100 MΩ – 1000 MΩ (1 MΩ), 1 GΩ – 10 GΩ (0.01 GΩ), 10 GΩ – 100 GΩ (0.1 GΩ), 100 GΩ – 1000 GΩ (1 GΩ), 1 TΩ – 10 TΩ (0.01 TΩ)
Accuracy1 MΩ – 100 GΩ: ±⁠(3% of reading + 5); 100 GΩ – 1000 GΩ: ±⁠(10% of reading + 5); 1 TΩ – 10 TΩ: ±⁠(20% of reading + 5)
Insulation resistance at 5000 V (±10%)
Ranges (resolution)2 MΩ – 20 MΩ (0.01 MΩ), 20 MΩ – 200 MΩ (0.1 MΩ), 200 MΩ – 2000 MΩ (1 MΩ), 2 GΩ – 20 GΩ (0.01 GΩ), 20 GΩ – 200 GΩ (0.1 GΩ), 200 GΩ – 2000 GΩ (1 GΩ), 2 TΩ – 10 TΩ (0.01 TΩ)
Accuracy2 MΩ – 200 GΩ: ±⁠(3% of reading + 5); 200 GΩ – 2000 GΩ: ±⁠(10% of reading + 5); 2 TΩ – 10 TΩ: ±⁠(20% of reading + 5)
DC voltage
Range (resolution)0.0 V – 1000 V (0.1 V)
Accuracy±⁠(5% of reading + 3 digits)
AC voltage
Range (resolution)0.0 V – 750 V (0.1 V)
Accuracy±⁠(5% of reading + 3 digits)
DC current
Ranges (resolution)1 mA – 6 mA (0.01 mA), 100 µA – 1000 µA (1 µA), 10 µA – 100 µA (0.1 µA), 1 µA – 10 µA (0.01 µA), 100 nA – 1000 nA (1 nA), 10 nA – 100 nA (0.1 nA), 1 nA – 10 nA (0.01 nA), 100 pA – 1000 pA (1 pA)
Accuracy100 nA – 6 mA: ±⁠(5% of reading + 2 digits); 10 nA – 100 nA: ±⁠(10% of reading + 5); 1 nA – 10 nA: ±⁠(20% of reading + 5); 100 pA – 1000 pA: ±⁠(30% of reading + 5)
Capacitance
Ranges (resolution)10 nF – 100 nF (0.1 nF), 100 nF – 1000 nF (1 nF), 1 µF – 10 µF (0.01 µF), 10 µF – 50 µF
Accuracy±⁠(10% of full scale + 5 digits)
Diagnostics
Absorption ratio (DAR) and polarization index (PI)Yes
Ramp test and filter testYes
General
Display4-digit LCD, 108 × 65 mm, with backlight
Data storage500 groups, with review and upload to PC
Power12.6 V rechargeable battery
Power consumptionStandby 30 mA max (backlight off); backlight on 42 mA max; measuring 200 mA max (backlight off)
Insulation between measuring leads and housing≥ 50 MΩ
Withstand voltageAC 3 kV, 50 Hz, 1 minute
DimensionsH 240 × W 188 × D 85 mm
WeightApprox. 2750 g
AccessoriesHigh-voltage test rod (red), high-voltage test leads (black and green), monitoring software CD, USB cable, charger, manual and certificate

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.