Hioki PQ3198 Power Quality Analyzer

Brand
Hioki
Model number
PQ3198

Class A power quality analyzer to IEC 61000-4-30 Edition 3: ±0.1% voltage accuracy, gapless recording, supraharmonics and transients to 6000 V peak up to 700 kHz. Main unit; current sensors sold separately.

Price and availability on request

Request a quote

Sent with the product details: Hioki PQ3198 Power Quality Analyzer.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Verify power problems in accordance with the IEC61000-4-30 Edition 3 Class A standard
  • High accuracy and continuous gapless recording (V: ±0.1% of nominal voltage, A: ±0.1% rdg. ±0.1% f.s., W: ±0.2% rdg. ±0.1% f.s.)
  • Broadband voltage range lets you measure even high-order harmonic (supraharmonic) components of up to 80 kHz
  • Maximum 6000 V peak transient voltage up to 700 kHz
  • Measure up to 6000 A AC
  • Two systems of power measurement and efficiency calculation for (ch 1, ch 2, ch 3) and ch 4
  • IEEE 519 Compliance harmonics measurement
  • Easily create reports with bundled PQ ONE application software
  • Optional GPS BOX for synchronizing multiple devices

Specifications

Specifications
Measurement line typeSingle-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement)
Voltage rangesVoltage measurement: 600.00 V rms Transient measurement 6.0000 kV peak
Current ranges500.00 mA to 5.0000 kA AC (depends on current sensor in use)
Power ranges300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use)
Basic accuracyVoltage: ±0.1% of nominal voltage Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Measurement items1. Transient voltage : 2 MHz sampling 2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz 3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle Current (1/2) RMS: half-cycle calculation 4. Voltage swell, Voltage dips, Voltage interruption 5. Inrush current 6. Voltage waveform comparison 7. Instantaneous flicker value: As per IEC61000-4-15 8. 200 ms frequency: Calculated as 10 or 12 cycles,40 to 70 Hz 9. 10 sec frequency: Calculated as the whole-cycle time during the specif
RecordRepeated ON: 1 year, Maximum recording event: 9999 × 366 days (up to 9999 events per day) Repeated off: 35 days, maximum recording event: 9999 events
InterfacesSD/SDHC memory card, LAN (HTTP server function / FTP function), USB2.0 (for communication)
Display6.5-inch TFT color LCD (640 × 480 dots)
Power supplyAC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery Pack Z1003 (Continuous use: 180 minutes, Charging time: Max. 5 hr 30 m with AC adapter)
Dimensions and mass300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D, 2.6 kg (91.7 oz) (including Battery Pack Z1003)
Supplied with
ContentsInstruction manual ×1, Measurement guide ×1, Voltage Cord L1000 ×1 set (Red/ Yellow/ Blue/ Gray each 1, Black 4, 3m (9.84ft) length, Alligator clip ×8), Spiral tube x20, Color clip, AC Adapter Z1002 ×1, Strap ×1, USB cable (1 m 3.28 ft length) ×1, Battery pack Z1003 ×1, SD Memory Card 2GB Z4001 ×1
Ordering
Order codePQ3198 (Main unit, current sensor is sold separately)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.