Hioki DT4253 Digital Multimeter

Brand
Hioki
Model number
DT4253

Digital multimeter with μA and mA DC ranges for 4 to 20 mA loops and flame currents, temperature, 1000 V AC/DC, clamp probe input to 1000 A and a low-pass filter.

Price and availability on request

Request a quote

Sent with the product details: Hioki DT4253 Digital Multimeter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Ideal for measuring currents ranging from instrumentation signals (4 to 20 mA) to flame currents (μA) with built in high-sensitivity current ranges (DT4253)
  • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
  • Dual display lets you check voltage and frequency simultaneously

Specifications

Specifications
DC Voltage range600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3% rdg. ±5 dgt.
AC Voltage range6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3)
AUTO AC/DCVYes
Resistance range600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±5 dgt.
DC Current range60.00 μA to 60.00 mA, 4 ranges, Basic accuracy: ±0.8% rdg. ±5 dgt.
From 4 to 20mA Percentage conversion displayYes
AC Current range (use with Clamp on probes)10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3)
Temperature (thermocouples)K: -40.0 to 400.0°C , Add the Temperature probe accuracy to basic accuracy: ±0.5% rdg. ±2°C
Voltage detectionN/A
Capacitance range1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt.
Frequency range99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage), Basic accuracy: ±0.1% rdg. ±1 dgt.
Continuity checkContinuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more
Diode testOpen terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V
Other functionsFilter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option), 4-20 mA percentage conversion
DisplayMain and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
Power supplyLR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
Dimensions and mass84 mm (3.31 in.)W × 174 mm (6.85 in.)H× 52 mm (2.05 in.)D, 390 g (13.8 oz.) (including batteries and holster)
Supplied with
ContentsTest lead L9300 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
Ordering
Order codeDT4253 (With mA DC, temperature)