Hioki BT3554-52 Battery Tester with Pin Type Lead L2020

Brand
Hioki
Model number
BT3554-52

Handheld battery tester that judges degradation (PASS, WARNING, FAIL) from internal resistance and voltage, even while the battery stays connected: 3 mΩ to 3 Ω, ±6 V to ±60 V. Supplied with pin type lead L2020.

Price and availability on request

Request a quote

Sent with the product details: Hioki BT3554-52 Battery Tester with Pin Type Lead L2020.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Battery measurement can be performed while the battery is connected to its host device, without taking it offline
  • Measure and save data in as fast as 2 seconds, a 60% improvement from the legacy 3554
  • Instantaneously diagnose battery degradation (PASS, WARNING, FAIL) by measuring internal resistance and voltage
  • Noise reduction technology improves noise resistance
  • Screen and audio guidance simplifies measurement
  • Measurement data is linked to site information and saved, reducing management man-hours
  • Easily transfer measurement data to your smartphone or tablet by using our free app GENNECT Cross or to an Excel® file. (Wireless Adapter Z3210 is necessary)
  • New protector delivers better ergonomic hold and durability in the field

Specifications

Specifications
Resistance measurement range3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt) Testing source frequency: 1 kHz ±30 Hz With function for avoiding noise frequency enabled: 1 kHz ±80 Hz Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range) Open terminal Voltage: 5 V peak
Voltage measurement range± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt
Temperature measurement accuracyMeasurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F) * When using the Clip Type Lead with Temperature Sensor 9460. * When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1"]). * When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94"]). BT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F)
Absolute max. input voltage60 V DC max. (No AC input)
Measurement time100 ms
Response timeApprox. 1.6 sec.
ComparatorCompares measured values with set threshold values to make judgments and reports them to the user. Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL If the judgment result is WARNING or FAIL, t
Memory functionalityOperation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units) Saved data: Saved measurement data is linked to profile information. 1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument. -1. Date and time -2. Resistance value, voltage value, and temperature -3. Comparator threshold value and judgment result 2. Profile information: Profile information can b
Measurement NavigatorOperation: Announces the next battery number to be measured via a screen display and audio guidance. Audio output is generated by a connected mobile device when using the Z3210 and a supported application (GENNECT Cross). Preparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument.
Communication interfaceUSB Bluetooth® wireless communications (when Z3210 installed)
Other functionsTemperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock
Power supplyLR6 (size AA) alkaline battery ×8 Rated supply voltage: 1.5 V DC × 8 (Nickel metal hydride batteries may be used. However, the battery life display is not supported in this configuration.) Continuous operating time: Approx. 8.3 hr. (without Z3210 installed), Approx. 8.2 hr. (with Z3210 installed and wireless communications active)
Dimensions and mass199 mm (7.83 in.)W × 132 mm (5.20 in.)H × 60.6 mm (2.39 in.)D (with protector), 960 g (33.9 oz.) (including batteries and protector)
Supplied with
ContentsCarrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap Z5043×1, USB cable L1003 ×1, AA alkaline battery (LR6) ×8, User Manual ×1; With Pin Type Lead L2020
Ordering
Order codeBT3554-52 (Bundled with Pin Type Lead L2020)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.