Fluke T6-600 Electrical Tester with FieldSense
- Brand
- Fluke
- Model number
- T6-600
Electrical tester with FieldSense: measures AC voltage and current through the fork without touching live conductors.
Price and availability on request
Key features
- Measure AC voltage and current without touching a live wire
- Troubleshoot with all power supply measurements at-a-glance
- See AC voltage and current values without test leads
Specifications
| Function, Requires test leads | Range; Resolution; Accuracy |
|---|---|
| FieldSense, ac voltage true-rms, No | 600 V; 1 V; ±(3% + 3 counts) 45 Hz - 66 Hz |
| FieldSense, ac current true-rms, No | 200.0 A; 0.1 A; ±(3% + 3 counts) 45 Hz - 66 Hz |
| Volts ac true-rms, Yes | 600 V; 1 V; ±(1.5% + 2 counts) 45 Hz - 66 Hz |
| Volts dc, Yes | 600 V; 1 V; ±(1% + 2 counts) |
| Resistance, Yes | 2000 Ω; 1 Ω; ±(1% + 2 counts) |
| Safety | 600 V CAT III; IEC/EN 61010-1: Pollution Degree 2 |
| Calibration | 1-year calibration cycle |
| Dimensions | 61.1 x 259.3 x 43.8 mm |
| Jaw opening | 17.8 mm |
| Weight | 0.35 kg (0.78 lb) |
| Temperature, Operating | -10 °C to +50 °C (14 °F to 122 °F) |
| Temperature, Storage | -30 °C to +60 °C (-22 °F to +140 °F) |
| Altitude, Operating | 2,000 m (6,562 feet) |
| Altitude, Storage | 10,000 m (32,808 feet) |
| Relative Humidity | 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F); 0% to 75%, 30°C to 40 °C (86 °F to 104 °F); 0% to 45%, 40°C to 50 °C (104 °F to 122 °F) |
| Battery Type and Life | 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense |
| Temperature coefficient | 0.1 x (specified accuracy); °C for <18°C or >28 °C; (< 64.4 °F or > 82.4 °F) |
| Contents | Attached test leads with removable 4 mm probe caps, user documentation |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the T6-600
The Fluke T6-600 measures AC voltage and current by sliding a wire into its open fork, using FieldSense technology, so no test lead contact with live metal is needed. All supply measurements are shown at a glance.