Fluke 922/KIT Airflow Meter Kit with Pitot Tube

Brand
Fluke
Model number
922/KIT
Category
Anemometers

Fluke 922 airflow meter / micromanometer kit with pitot tube, for pressure, air velocity and air flow.

Price and availability on request

Request a quote

Sent with the product details: Fluke 922/KIT Airflow Meter Kit with Pitot Tube.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Powerful meter provides differential and static pressure, air velocity and flow readings
  • Convenient colored hoses help proper interpretation of pressure readings
  • Easy to use without sacrificing performance
  • Bright, backlit display for clear viewing in all environments
  • User-defined duct shape and size for maximum airflow accuracy
  • Resolution down to 0.001 in H2O
  • 99 point data storage capacity
  • Min/Max/Average/Hold functions for easy data analysis

Specifications

Technical Specifications
Air pressure, Range, Resolution, Accuracy±4000 Pascals; 1 Pascal; ±1% + 1 Pascal; ±16 inH2O/ 0.001 inH2O/±1% + 0.01 inH2O; ±400 mmH2O/ 0.1 mmH2O; ±1% + 0.1 mmH2O; ±40 mbar /0.01 mbar; ±1% + 0.01 mbar; ±0.6 psi; 0.0001 psi /±1% + 0.0001 psi
Air velocity, Range, Resolution, Accuracy250 to 16,000 fpm; 1 fpm; ±2.5% of reading at 2000 fpm (10.00 m/s); 1 to 80 m/s; 0.001 m/s; ±2.5% of reading at 2000 fpm (10.00 m/s)
Air flow (volume), Range, Resolution, Accuracy0 to 99,999 cfm; 1 cfm; Accuracy is a function of velocity and duct size; 0 to 99,999 / 1 m3/hr / Accuracy is a function of velocity and duct size; 0 to 99,999 l/s; 1 l/s; Accuracy is a function of velocity and duct size
Temperature, Range, Resolution, Accuracy0°C to 50°C; ±1% + 2°C; 0.1°C; 32°F to 122°F; ±1% + 4°F; 0.1°F
General Specifications
Operating temperature0°C to +50°C (+32°F to +122°F)
Storage temperature-40°C to +60°C (-40°F to +140°F)
Relative humidity0% to 90%, non-condensing
IP ratingIP40
Operating altitude2000 m
Storage altitude12000 m
VibrationMIL-PREF-28800F, Class 3
Max pressure at each port10 psi
Data storage capacity99 readings
Warranty2 years
Power, battery lifeFour AA batteries
Battery life280 hours without backlight, 60 hours with backlight

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 922/KIT

This kit supplies the Fluke 922 airflow meter and micromanometer with a pitot tube, ready for duct velocity and flow measurements as well as differential and static pressure. The meter has colour-coded hoses and a backlit display.