Fluke 902 FC True-rms HVAC Clamp Meter

Brand
Fluke
Model number
902 FC

True-rms HVAC clamp meter with Fluke Connect: 200 µA DC for flame sensors, resistance to 60 kΩ, capacitance, temperature.

Price and availability on request

Request a quote

Sent with the product details: Fluke 902 FC True-rms HVAC Clamp Meter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • A wireless Fluke Connect-enabled clamp meter designed specifically for the needs of HVAC technicians
  • Offers 200 µA DC current measurements to measure flame rod
  • Extends resistance range to measure thermistors up to 60kΩ
  • Captures flue gas temperature
  • Measures start and run motor capacitors
  • Measures variable frequency drive performance

Specifications

A ac (via Jaw)
A ac (via Jaw), Resolution0.1 A
A ac (via Jaw), Accuracy2.0% ±5 digit (45-65 Hz); 2.5% ±5 digit (65-400 Hz)
A ac (via Jaw), Range600.0 A
A ac (via Jaw), Crest Factor (50Hz or 60Hz)2.5 MIN@220 A; > 1.4 MIN@600 A; Add 2% for CF>400 A
V acCrest Factor (50Hz or 60Hz)
V ac, Resolution0.1 V
V ac, Accuracy1.5% ±5 digits
V ac, Range600.0 V
V dc
V dc, Resolution0.1 V
V dc, Accuracy1.5% ±5 digits
V dc, Range600.0 V
Ohms
Ohms, Resolution0.1/1/10
Ohms, Accuracy1% ±5 digits
Ohms, Range600/6000/60.00 kΩ
Capacitance
Capacitance, Resolution0.1/1 µF
Capacitance, Accuracy1% ±4 digits
Capacitance, Range100.0/1000 µF
µA
µA, Resolution0.1 µA
µA, Accuracy1% ±5 digits
µA, Range200 µA
Contact temperature
Contact temperature, Resolution0.1 C/F
Contact temperature, Accuracy1% ±8 digits
Contact temperature, Range-40 to 400 °C (-40 °F to 752 °F)
Continuity beeper
Continuity beeper, Beeper volume75 dBA nom. 15 cm. from case front
Continuity beeper, On threshold<=30 Ω
Mechanical and General Specifications
Maximum voltage between any terminal and earth ground600 V
Battery type2 AA alkaline batteries, NEDA 15A, IEC LR6
TemperatureOperating: -10 °C to +50 °C (14 °F to +122 °F); Storage: -40 °C to +60 °C (-40 °F to +140 °F)
Operating humidityNon condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))
AltitudeOperating: 3,000 m (9,842 ft); Storage: 12,000 m (39,370 ft)
Dimensions230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)
Weight (meter only)419 g (15 oz)
SafetyIEC 61010-1, Pollution Degree 2; IEC 61010-2-032: CAT III 600 V; CAT IV 300 V; IEC 61010-2-033: CAT III 600 V; CAT IV 300 V
IP RatingIEC 60529: IP30, non-operating
Temperature coefficientsAdd 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 902 FC

The Fluke 902 FC is designed around HVAC service. It measures microamps for flame and pilot sensors, resistance up to 60 kΩ for thermistors, motor start and run capacitors and temperature, and sends readings to the Fluke Connect app. Rated CAT III 600 V / CAT IV 300 V.