Fluke 54 II B Dual Input Data Logging Thermometer

Brand
Fluke
Model number
54 II B

Dual-input logging thermometer storing 500 points, with recall on the display and infrared USB export.

Price and availability on request

Request a quote

Sent with the product details: Fluke 54 II B Dual Input Data Logging Thermometer.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX, or AVG
  • Recall function allows logged data to be easily reviewed on the meter display
  • Infrared USB communication port allows data to be exported to optional FlukeView Forms Temperature PC software for further analysis and graphing
  • Data Logging up to 500 points of data with user adjustable recording interval
  • Relative time clock on MIN, MAX, and AVG provides a time reference for major events
  • Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
  • Measures J, K, T, E, R, S, and N-type thermocouples
  • Readout in °C, °F, or Kelvin (K)

Specifications

General Specifications
Temperature accuracy, Above -100°CJ, K, T, E, and N-type: ±[0.05% + 0.3°C]1; R and S-type: ±[0.05% + 0.4°C]1
Temperature accuracy, Below -100°CJ, K, E, and N-types: ±[0.20% + 0.3°C]1; T-type: ±[0.50% + 0.3°C]
Temperature, J-type-210°C to 1200°C
Temperature, K-type-200°C to 1372°C
Temperature, T-type-250°C to 400°C
Temperature, E-type-150°C to 1000°C
Temperature, N-type-200°C to 1300°C1
Temperature, R and S-type0°C to 1767°C1
Temperature scaleITS-90
Applicable standardsNIST-175
Display resolution0.1°C, 0.1 K < 1000; 1°C, 1 K ≥ 1000
Environmental Specifications
Operating temperature-10°C to 50°C
Storage temperature-40°C to 60°C
Humidity (without condensation)0% to 90%; 0°C to 35°C; 0% to 70%; 0°C to 50°C
Safety Specifications
Overvoltage categoryCSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2
Mechanical and General Specifications
Size (L x W x D)173 x 86 x 38 mm
Weight400 g
Batteries3 AA batteries; typical 1000-hour life
Supplied with
ContentsImpact absorbing holster; Two 80PK-1 bead probe thermocouples

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 54 II B